00195094-0202-MM-D3_EN.pdf - 第39页

SIPLACE D3 8 2-monthly maintenance jobs 08/2008 US Edition 39 8 Y ou will need for the 2-mo nthly maintenance jobs: 8 – V acuum cleaner with appropriate nozzle – Condensate drip tray – Short-bristled brush – Phillips scr…

100%1 / 98
8 2-monthly maintenance jobs SIPLACE D3
08/2008 US Edition
38
8 2-monthly maintenance jobs
8
SIPLACE D3 8 2-monthly maintenance jobs
08/2008 US Edition
39
8
You will need for the 2-monthly maintenance jobs: 8
Vacuum cleaner with appropriate nozzle
Condensate drip tray
Short-bristled brush
Phillips screwdriver
Whetstone
Scissors
Lint-free cloths
ISOFLEX TOPAS NCA52 grease
UNISILKON L250L
Interflon Teflon spray
–WD40
New compressed air filter 3/4 µm, if required
New filters, if required
New silencer for the Collect&Place head, if required.
8
: Switch the placement machine off at the main switch.
8
Check or replace the compressed air filter 8
a Use the machine key to open the door to the compressed air supply, detach the cable and re-
mov
e the door.
s Turn the main compressed air valve clockw
ise.
All manometers must be set to zero.
d Loosen the screw to the compressed air supply.
f Remove the compressed air supply.
: Place a drip tra
y
beneath the compressed air maintenance unit.
g Open the screw beneath the cover cap to release the pressure.
h Unscrew the cap from the compressed air maintenance unit.
8
Use an appropriate strap wrench, if you cannot remove the cap by hand. 8
8
j Unscrew the filter from the compressed air maintenance unit and check for dirt.
: Replace the filter if it is dirty.
: Revers
e the sequence described above to refit the filter and filter casing.
8 2-monthly maintenance jobs SIPLACE D3
08/2008 US Edition
40
8