00195094-0202-MM-D3_EN.pdf - 第66页
10 Annual maintenance work SIPLACE D3 08/2008 US Edition 66 10

SIPLACE D3 10 Annual maintenance work
08/2008 US Edition
65
10
You will need for the annual maintenance jobs: 10
– Phillips screwdriver
– Set of hexagon socket spanners
– Lint-free cloths
– Ethyl alcohol
– SIPLACE cleaning tissue
– ISOFLEX TOPAS NCA52 grease
– Grease gun
– SIPLACE cleaning tissue
– Klüberplex BEM 34-132
– Grease nipple
– Cooling air hoses
– Gas spring(s) in protective cover, if required.
10
There must be no PCBs on the PCB conveyor for the following jobs. 10
: Open both protective covers on one side of the machin
e (locations 1+2 and 3+4).
10
Push the gantry carefully and gently using the handle on the head (not on the end buffers). 10
10
: Move the gantry over the feeder modules. This will stop it outside your working area.
10
Clean and preserve the PCB conveyor 10
a Clean and preserve the recirculating ball screw by
running a SIPLACE cleaning tissue along
the thread of the screw.
s Clean and grease the sliding surfaces of the guide
rails using a SIPLACE cleaning tissue.
: Clean and preserve the hexagonal shafts using a SIPLACE cleaning tissue.
: Check that
the
entire PCB conveyor mechanism (conveyor, width adjustment, clamping unit)
moves easily.
Carry out the necessary maintenance if it does not move easily.
10
Clean the fixing strip (PCB conveyor) 10
d Clean the fixing strip of the width adjustment clam
ping unit using a lint-free cloth moistened
with ethyl alcohol.

10 Annual maintenance work SIPLACE D3
08/2008 US Edition
66
10

SIPLACE D3 10 Annual maintenance work
08/2008 US Edition
67
Function test of used tape cutter 10
a Introduce a DIN A3 sheet of paper or two DIN A4 sheet
s stuck together into the used tape
channel.
10
One DIN A4 sheet on its own is too short to reach the tape cutter. 10
10
10
s Use adhesive tape to stick the sheet(s) to the used tape channel.
10
Make sure that no paper protrudes into the traveling range of the placement head. 10
10
10
d Log on to the station as a service engineer and start SITEST.
d In the taskbar, click on the Component tables button.
d In the view that appears, click on "Activate tape cutter".
10
: Remove the sheet of paper from the used tape channel.
Contact your Regional Service Center if it is not cut through cleanly.
10
10