SIPLACE D3 9 4-monthly maintenance jobs 08/2008 US Edition 49 Remember to follow the ESD regulations. 9 9 9 : Cover the feeder area to protect th e feeder modules and fro nt part of the head. 9 a Open the strain relief. …

9 4-monthly maintenance jobs SIPLACE D3
08/2008 US Edition
48

SIPLACE D3 9 4-monthly maintenance jobs
08/2008 US Edition
49
Remember to follow the ESD regulations.
9
9
9
: Cover the feeder area to protect the feeder modules and front part of the head.
9
a Open the strain relief.
s Open the retainer over the ribbon cables.
d Pull out the two ribbon cables.
9
f Loosen the 4 screws on the front part of head (using the 3 mm socket-head spanner) and re-
move the front part.
Hold the front part of head firmly as you remove the screws. 9
Be careful not to touch the distributor. 9
9
Turn the star half a revolution to avoid damaging the valve plunger drive with the valve plunger.9
9
: Place the front part of head on a soft ESD surface (with the valve plunger side underneath) or
place it on a suitable head stand.
: Remove the sleeves and place them in the containers provided.
9

9 4-monthly maintenance jobs SIPLACE D3
08/2008 US Edition
50
9