3OM-1751-002w_G5S.pdf - 第143页

3OM-1751 1-89 6.3.1 "Light Board" T ab [1] [2] [4] [3] F3A72 [1] Result Displayed is the lighting board check result. [2] Error code Displayed is the lighting board error code. [3] V ersion When the diagnosis i…

100%1 / 268
3OM-1751
1-881303-001
6.3 "RECOG" Window
This window enables you to check the I/O signals for the component and PEC
recognition operations.
[1]
F3A71
[1] Tabs
The "RECOG" window is provided with the following ve tabs.
When each tab is pressed, the corresponding tab sheet appears.
Tabs Description
Light Board
The corresponding tab sheet enables the operator to diagnose the lighting.
Recog Light
The corresponding tab sheet enables the operator to check the component
recognition lighting or PEC recognition lighting.
Capture Img.
The corresponding tab sheet enables the operator to check the component
recognition camera or PEC recognition camera.
Count Board
In this tab sheet the beam count value is checked and the wire connection
condition and counter board condition are conrmed.
Others
In this tab sheet, the optional 2-D bar code read license (GS-DL100) check is
performed.
T3A11
6.3 "RECOG" Window
Graphic
Development
3OM-1751
1-89
6.3.1 "Light Board" Tab
[1]
[2]
[4]
[3]
F3A72
[1] Result
Displayed is the lighting board check result.
[2] Error code
Displayed is the lighting board error code.
[3] Version
When the diagnosis is performed and there is no problem in the result, the
rmware version for the lighting control panel is displayed.
[4] [CHECK] Button
When this button is pressed, the lighting control board check is executed.
1303-001
6.3 "RECOG" Window
Graphic
Development
3OM-1751
1-90
6.3.2 "Recog Light" Tab
[1]
F3A73
[1] Tabs
The "Recog Light" window is provided with the following two tabs. When
each tab is pressed, the corresponding tab sheet appears.
Tabs Description
Cmp. Recog
In this tab sheet the component recognition lighting is turned ON in
the minimum unit and the wire connection condition and illumination
condition are conrmed.
PEC Recog
In this tab sheet the PEC recognition lighting is turned ON and the wire
connection condition and illumination condition are conrmed.
T3A12
1303-001
6.3 "RECOG" Window
Graphic
Development