3OM-1751 1-45 1303-001 [T each Start] button When pressed, this button executes the teaching operation. Based on the captured image, the magnication offset for the component recognition camera is calculated. [Jig Colct]…

3OM-1751
1-441303-001
5.7 "Cmp Recog Mag" Window
The corresponding window enables you to perform a teaching operation on the
magnication of the Component recognition camera.
[1]
[2]
F3A33
[1] Teaching Data Display Section
Displayed are the magnications for the designated camera and head.
[2] Teaching Procedure Display Area
Displayed are the buttons to be used for the teaching operations.
Select camera
Each component recognition camera in the graphic image of the machine is
provided with a button function. When a button is pressed, the corresponding
component recognition camera is selected as an object one for the teaching
operation.
Select head
In this section, the buttons showing the component recognition cameras
corresponding to each head are displayed as images.
Select the component recognition camera for which the teaching is
performed.
[Jig Attach Pos Move] button
Using this function, the head is moved to the position where the
magnication teaching glass jig is easily attached.
Graphic
Development
5.7 "Cmp Recog Mag" Window

3OM-1751
1-451303-001
[Teach Start] button
When pressed, this button executes the teaching operation.
Based on the captured image, the magnication offset for the component
recognition camera is calculated.
[Jig Colct] button and [Vac OFF] button
Using this function, the head is moved to the position where the
magnication teaching glass jig is easily removed.
[Save] button
When this button is pressed, the teaching results are saved.
•
Component Recognition Camera Magnication Teaching Jig
For the component recognition camera magnication teaching, the following
jig component is used.
Magnication Teaching Glass Jig JG-0084
(KYF-M8673-00, Component Recognition Calibration Jig)
On the bottom surface of the jig component, 576 black circles with
f
1.00 [mm]
are vapor-deposited at 2.00 [mm] pitch.
50 mm
50 mm
Magnication Teaching Glass Jig F3A34
Jig Pick-up Nozzle
For the pick-up of the magnication teaching glass jig, the nozzle VF02 for
middle-size odd shaped nozzle is used.
5.7 "Cmp Recog Mag" Window

3OM-1751
1-461303-001
•
Component Recognition Camera Magnication Teaching Procedure
Procedure
(1) Press the Camera and Head selection buttons and select the camera and head
to be taught.
Note
The teaching operations for four combined patterns are performed.
Camera 1 – Head #1
Camera 1 – Head #2
Camera 2 – Head #1
Camera 2 – Head #2
(2) Press the [Jig Attach Pos Move] button and within 10 seconds, press the
[START] button on the operation panel.
(The head will move to the position where the magnication teaching glass
jig is to be picked up (jig attachment position)).
(3) Setup the nozzle VF02 for middle-size odd shaped nozzle onto this end of the
head moved to the jig setup position and pick up the magnication teaching
glass jig so that the image is within the recognition area.
Note
When the jig is to be picked up using the nozzle, hold the right and left
ends of the jig to pick it up.
Notice
When the vacuum pump is not activated, cancel the test operation
mode or remove a check mark from the item for vacuum pump stop
in the test operation mode window.
(4) Press the [Teach Start] button.
(Based on the captured image, the magnication offset for the component
recognition camera will be calculated.)
(5) Press the [Jig Colct] button and within 10 seconds, press the [START] button
on the operation panel.
(The beam will move to the position where the magnication teaching glass
jig can be removed).
(6) Remove the magnication teaching glass jig.
(7) Press the [Vac OFF] button to turn off the vacuum and remove the nozzle
used for the teaching.
(8) Press the [Save] button to save the teaching results.
5.7 "Cmp Recog Mag" Window