3OM-1751 2-85 1303-001 [7] Output PCB delivery position [mm] Set the PCB delivery position. [8] Output PCB delivery speed [mm/sec] Set the PCB delivery speed. • Default : 300 [mm/sec] Note When the unloading system of th…

3OM-1751
2-841303-001
[4] Input conveyor Timer1 [sec]
Set the time to limit the operating time (PCB reception from the input
machine) of the input conveyor.
This timer measures the operating time of the input conveyor and is used to
detect an interrupted PCB.
Note
Add 2 seconds (approx.) to the time required for PCB reception from the
input machine and set the time in the text box.
[5] Input Pusher delay timer [sec]
When "Pusher" is set in the "Input mode" text box of the label "Input Setup",
it is required to specify the delay (waiting) time for the loading action to start
after the inlet sensor has detected a PCB.
[6] Output mode
The PCB delivery to the output machine is set in this section.
Standard
When the output machine is manufactured by us, set "Standard" in the
text box.
When the work request signal is received from the output machine, the
PCB transfer signal of the machine is turned ON and a PCB is transferred
to the output machine by the output conveyor.
When the work request signal is not turned OFF within the specied time
after a PCB unloading action has started, the machine stops in an error
condition.
Interval
When the work request signal of the output machine is turned ON, PCBs
on the machine side are transferred to the output machine.
The conveyor stops when the output conveyor timer 1 has reached the
specied time.
The machine starts its unloading actions when the unloading condition is
fullled after the conveyor has stopped running and the time specied in
the "Output interval timer [sec]" text box has elapsed.
Note
No error detection is made.
SMEMA
PCBs are transferred according to the "SMEMA" standard.
3.2 "PCB Transfer Mode" Tab Sheet

3OM-1751
2-851303-001
[7] Output PCB delivery position [mm]
Set the PCB delivery position.
[8] Output PCB delivery speed [mm/sec]
Set the PCB delivery speed.
•
Default
: 300 [mm/sec]
Note
When the unloading system of the output machine is used in a mode other
than the standard one and the PCB transfer speed of the output machine
is slow, the transfer speed must be adjusted to one on the output machine
side.
[9] Output conveyor Timer #1 [sec]
Set the time to limit the operating time (PCB reception by the output
machine) of the output conveyor.
Note
Add 2 seconds (approx.) to the time required for PCB reception by the
output machine and set the time in the text box.
[10] Output interval timer [sec]
When "Interval" is set in the "Output mode" text box, set the time as interval
time for PCB unloading actions.
[11] Output Pusher conveyor wait [sec]
When "SMEMA" is set in the "[9] Output mode" text box, the output
conveyor wait time is set in this text box.
3.2 "PCB Transfer Mode" Tab Sheet

3OM-1751
2-861303-001
4. "MACH SETUP" Window
4.1 "General" Tab Sheet
[1]
[2]
[3]
[5]
[4]
[7]
[6]
[9]
[10]
[11]
[8]
F3B78
[1] Netwk.Dt.
[Set] Button
When this button is pressed, the "Netwk Setup" window appears.
F3B79
[Machine Name] Button
Using this button, the machine name is set to identify it on the network.
IP Address
The IP address and subnet mask used on the network are set in this section.
4. "MACH SETUP" Window