FK-9F98-29 XP Series Training Text for Service Engineers
Edition 5.0 XP241 – Chapter 6 Proper Data Measurements Page 1 of 20
Fuji Machine Mfg. Co., Ltd. Okazaki.
SMT Equipment Quality Assurance Dept.
6 – 1 CS Section
Chapter 6 – Proper Data Measurements
6.1 Adjusting the mark camera
Mark camera setting (XC-55)
1. Set the mark camera settings and aperture as follows:
Signal 1N
Gain M
Note: ensure the lens unit is fastened to the camera unit with adhesive (Loctite 425).
Note: When attaching the camera unit to the installation bracket, tighten the bolts with
0.38N.m to 0.57N.m force, and apply adhesive (Loctite222) to the bolts.
Camera focus
Jig: Plate jig (AJPJ-0060).
Jig: Color sample disc for brightness measurement (brightness value of 130).
1. Clamp the Plate jig in the main table.
2. Temporarily remove the lighting unit.
3. Remove the mark camera lens cover.
4. Reattach the lighting unit making sure it is pushed right up against the lip of the
camera installation bracket.
5. Install the mark camera in the machine and set the height of the camera so that the
clearance between the bottom of the lighting unit and the plate jig is greater than 61
mm (61.5mm is ideal). This is to ensure that there is sufficient clearance between
the lighting unit and the nozzle change platform.
Plate jig
greater than 61mm
When attaching the
lighting unit, push it
against the camera
installation BKT.
Focus adjustment, first,
remove the lens cover.
After the focus is adjusted
re-attach the lens cover.
Gap between lens cover
and light source should be
0.5mm
Hollow bolt
to lock the
lens
Adjust the focus by
rotating the tip of the lens.
A: Camera installation BKT
A F M
GAIN
SIGNAL
1N
1I
VIDEO OUT/DC IN/SYNC
Top view of the camera
FK-9F98-29 XP Series Training Text for Service Engineers
Edition 5.0 XP241 – Chapter 6 Proper Data Measurements Page 2 of 20
Fuji Machine Mfg. Co., Ltd. Okazaki.
SMT Equipment Quality Assurance Dept.
6 – 2 CS Section
6. Select [Maintenance A] – [JOG] and [Fiducial]. The light comes ON for the mark
camera, and the raw image is displayed on the monitor.
7. Adjust the focus ring on the mark camera so that the markings on the plate jig come
into clear, sharp focus.
8. Lock the focus ring and apply adhesive (Loctite 425) to the lens lock hollow bolts.
9. Remove the light source unit.
10. Install the lens cover.
11. Replace the light source unit right up against the lip of the camera installation
bracket.
12. Set the position of the lens cover so that there is 0.5mm clearance between the
bottom of the lens cover and the top of the light source unit:
Camera Brightness Measurement
1. The lighting unit contains two different light sources. One (light source A) is the ring
of diodes at the bottom of the unit. The other (light source B) is the rectangular light
emitter found above the ring of diodes.
2. Place the color sample disc on the mark camera jig plate and bring the mark
camera above the disc.
3. Select [Maintenance A] – [Jog] – [Fiducial].
4. Confirm that the two LED lights for A and B are ON:
5. With the mark camera centered on the color sample disc touch the screen to display
a brightness reading.
6. Adjust the camera gain so that the brightness becomes around 120.
0.5mm
A
B
FK-9F98-29 XP Series Training Text for Service Engineers
Edition 5.0 XP241 – Chapter 6 Proper Data Measurements Page 3 of 20
Fuji Machine Mfg. Co., Ltd. Okazaki.
SMT Equipment Quality Assurance Dept.
6 – 3 CS Section
6. 2 Measuring the mark camera resolution
Equipment: Glass gage for mark camera resolution measurement (Z3502DFAJ0020).
1. Clamp the glass gage in the main table. Ensure it is flush with the reference rail.
2. Select [Maintenance A] – [Jog] – [Fiducial] to display the mark camera live image.
3. Bring the mark camera above the center of the glass gage and select the cross
hairs.
4. Inch the mark camera until it is centered on the center dot in the image (if the image
is too bright then ensure the emergency switch is pressed and then use your hand
to shade the mark camera until the dots on the glass gage become visible) :
5. Select [Maintenance A] – [I/O Check] – [Y010 Fiducial Lamp] – ON.
6. Select [Program] – [Template editor] – and then right click on the screen to display a
menu box.
7. Select [Utility] – [Default Setting] and confirm that the default settings are identical
to those shown below:
The reference rail
Push the glass gauge against the
reference rail and clamp the gauge.
The glass gauge should be
printed side up.