FK-9F98-29 XP Series Training Text for Service Engineers
Edition 5.0 XP241 – Chapter 8 Options Page 8 of 10
Fuji Machine Mfg. Co., Ltd. Okazaki
SMT Equipment Quality Assurance Dept.
8 – 8 CS Section
Resolution measurement
1. Select [Maintenance A] – [I/O Check] and turn (Y01C CoplanarityLed) ON.
2. Select [Program] – [Template Editor].
3. Right click on the screen with a mouse and select [Utility] – [Scale Setting] to open the
“Camera Unit Ctrl” dialogue.
4. Click on the “scale setting” button to open up the scale setting screen as shown in the
picture below:
5. In the “Scale” dialogue input “20mm” in the “X_size” box.
6. Use the mouse to drag the two vertical caliper lines so that they are aligned with the left
and right edge of the coplanarity camera jig as shown in the picture below. There is no
need to align the horizontal caliper lines.
7. Once the two vertical caliper lines have been aligned with the jig and “20mm” input in
the “X_size” box, click on OK to return to the “Camera Unit Ctrl” dialogue.
8. Here the X-unit resolution figure should have been saved in the dialogue.
9. Now it is necessary to copy over the X_unit resolution figure to the Y_unit. To do this,
20mm
Scale
Setting
1

FK-9F98-29 XP Series Training Text for Service Engineers
Edition 5.0 XP241 – Chapter 8 Options Page 9 of 10
Fuji Machine Mfg. Co., Ltd. Okazaki
SMT Equipment Quality Assurance Dept.
8 – 9 CS Section
simply click on the right pointing arrow key on the “Camera Unit Ctrl” dialogue:
10. Having done this confirm that the resolution figures are within the tolerances shown
below:
Resolution Tolerances
X_Unit 0.0626 ~ 0.0686
X_View 40.1 ~ 43.9
Y_Unit 0.0626 ~ 0.0686
Y_View 30.06 ~ 32.94
11. Finally click on the “OK” button in the “Camera Unit Ctrl” dialogue then right click on the
screen and select return.
12. Select [Manual Operation] – [Nozzle Operation] – [Place] – [Execute] – [START] to
return the coplanarity jig to the nozzle station.
13. Finally remove the nozzle jig from the nozzle station and select [Maintenance A] – [I/O
Check] – and turn (Y01C CoplanarityLed) OFF.
14. Note that as with other cameras, the set screws for the focus and aperture rings should
be tightened securely and fastened with adhesive.
1
Click here to
copy
the X resolution
figures to Y

FK-9F98-29 XP Series Training Text for Service Engineers
Edition 5.0 XP241 – Chapter 8 Options Page 10 of 10
Fuji Machine Mfg. Co., Ltd. Okazaki
SMT Equipment Quality Assurance Dept.
8 – 10 CS Section
NOTES: