xp141-241-341-5.0E.pdf - 第220页
XP Proper Data List V1.40 14/11/2002 Item XP141 XP241 XP341 Description Reboot ______NOZZLE_DIAMETER______ = 0 0 0 __Nzl1Diameter = 0 0 0 Diameter of pickup nozzle (mm) User cannot edit __Nzl2Diameter = 0 0 0 Diameter of…

XP Proper Data List V1.40
14/11/2002
Item
XP141
XP241
XP341
Description
Reboot
X_RemoverPos
=
0
110
0
Tray remover position X
Calibrated data
Y_RemoverPos
=
0
1093
0
Tray remover position Y
Calibrated data
Z_RemoverPos
=
0
0
0
Tray remover position (Height) Z
Calibrated data
______DISPOSE_POSITION_____
=
0
0
0
X_Disposal1
=
346.5
351.5
346.5
Small NG parts eject position (from FD camera)
Calibrated data
X_Disposal2
=
0
0
2.5
XP341Tray NG parts eject position X
Calibrated data
Y_Disposal1
=
202.4
206
209.5
Small NG parts eject position (from FD camera)
Calibrated data
Y_Disposal2
=
0
0
240.5
XP341 Tray NG parts eject position Y
Calibrated data
Z_Disposal2
=
0
1
29.3
Large NG parts eject position (from FD camera)
Calibrated data
_______PRIZM_POSITION______
=
0
0
0
__PrismFront
=
136.5
147
147
Camera image acquiring position at Side 1
Calibrated data
__PrismBack
=
676.5
687
687
Camera image acquiring position at Side 2
Calibrated data
________JIG_POSITION_______
=
0
0
0
X_JigPickPos1
=
127.5
157.1
157.1
XP141:Jig (Large) pickup position XP241 Jig pickup position XP341Jig pickup position
Calibrated data
X_JigPickPos2
=
137.5
0
0
XP141:Jig (Middle) pickup position
Calibrated data
X_JigPickPos3
=
147.5
0
0
XP141:Jig (Small) pickup position
Calibrated data
Y_JigPickPos
=
209.05
207.75
211.75
XP141:Jig pickup position XP241:Jig pickup position XP341:Jig pickup position
Calibrated data
Z_JigPickPos
=
0.7
3.5
3.5
Jig pickup height
Calibrated data
_________ELEGANCE__________
=
0
0
0
__PlaceEleganceQ
=
0
0
0
XP241 & 341 ?-axis servo acceleration of placement (0.01~1) When 0 is set, it is 1.0
User cannot edit
__PlaceUpSpeedRatio
=
0
0.07
0.07
This is for XP241, 341 Nozzle raise speed factor after placement Speed factor 0.01 ~ 1.00. (Only for VT100 and VT20)
User can edit
__PlaceUpMaxSpeed
=
0
1000
1000
Maximum speed spec. for Z-axis motion speeed after parts placement. (Inputting range: 100.0 ~ 1000.0 [mm/s]
User can edit
__CycleStealElegance
=
1
1
1
The cycle steal elegance value setting. The cycle steal is carried out when passing the "waiting for the next process "over the __CycleStealTime.
User can edit
_________F_GLASS_VALUE__________
=
0
0
0
XMainStDecelPos
=
0
0
0
*2 Board deceleration position X [T1.12f]
User cannot edit
YMainStDecelPos
=
0
0
0
*2 Board deceleration position Y [T1.12f]
User cannot edit
XMainStArrivPos
=
0
0
0
*2 Board arrival position X [T1.12f]
User cannot edit
YMainStArrivPos
=
0
0
0
*2 Board arrival position Y [T1.12f]
User cannot edit
___________TRAY____________
=
0
0
0
T_TrayOrg
=
0
465
0
T-axis position at tray 101 (shuttle extend position)
Calibrated data
T_TrayEmptyOrg
=
0
495
0
T-axis position to detect empty on tray 101
Calibrated data
U_ShuttleBackwardOfst
=
0
0
0
Offset value at shuttle retract limit
Calibrated data
U_ShuttleForwardOfst
=
0
0
0
Offset value at shuttle extend limit
Calibrated data
U_ShuttleClampPos
=
0
488
0
Shuttle clamp position [mm]
Calibrated data
__ShuttleClampOfst
=
0
0
0
Tray shuttle clamp stroke offset [mm] (For the tray unit which is modified, The setting (__TrayUnitType =1) is only valid. Inputting range : -1.5 to +1.5. Calibrated data
__ElevotorOfst2
=
0
0
0
T-axis offset of the possible forward amount of tray No.11*. [mm]
Calibrated data
__ElevotorOfst3
=
0
0
0
T-axis offset of the possible forward amount of tray No.12*. [mm]
Calibrated data
__ElevotorOfst4
=
0
0
0
T-axis offset of the possible forward amount of tray No.13*. [mm]
Calibrated data
__ElevotorOfst5
=
0
0
0
T-axis offset of the possible forward amount of tray No.14*. [mm]
Calibrated data
__ElevotorOfst6
=
0
0
0
T-axis offset of the possible forward amount of tray No.15*. [mm]
Calibrated data
__ElevotorOfst7
=
0
0
0
T-axis offset of the possible forward amount of tray No.16*. [mm]
Calibrated data
__ElevotorOfst8
=
0
0
0
T-axis offset of the possible forward amount of tray No.17*. [mm]
Calibrated data
__ElevotorOfst9
=
0
0
0
T-axis offset of the possible forward amount of tray No.18*. [mm]
Calibrated data
__ElevotorOfst10
=
0
0
0
T-axis offset of the possible forward amount of tray No.19*. [mm]
Calibrated data
__TrayPickUpOfstZ
=
0
0
0
Tray parts pickup height offset [mm] *But the value less than -3.0 or more than +3.0 does not offset.
User can edit
________PLACE_OFFSET_______
=
0
0
0
__PlaceGlobalOfstX
=
0
0
0
Placement offset X (Valid only with VT10, 18, 20)
User cannot edit
__PlaceGlobalOfstY
=
0
0
0
Placement offset Y (Valid only with VT10, 18, 20)
User cannot edit
__PlaceGlobalOfstQ
=
0
0
0
Placement offset Q (Valid only with VT10, 18, 20)
User cannot edit
__PlaceGlobalOfstXR
=
0
0
0
Placement offset X (Valid only with VT10, 18, 20)
User cannot edit
__PlaceGlobalOfstYR
=
0
0
0
Placement offset Y (Valid only with VT10, 18, 20)
User cannot edit
__PlaceGlobalOfstQR
=
0
0
0
Placement offset Q (Valid only with VT10, 18, 20)
User cannot edit
__PlaceOfstForFidCamAngX
=
0
0
0
Placement offset X (mm)
User cannot edit
__PlaceOfstForFidCamAngY
=
0
0
0
Placement offset Y (mm)
User cannot edit
7/10

XP Proper Data List V1.40
14/11/2002
Item
XP141
XP241
XP341
Description
Reboot
______NOZZLE_DIAMETER______
=
0
0
0
__Nzl1Diameter
=
0
0
0
Diameter of pickup nozzle (mm)
User cannot edit
__Nzl2Diameter
=
0
0
0
Diameter of pickup nozzle (mm)
User cannot edit
__Nzl3Diameter
=
0
0
0
Diameter of pickup nozzle (mm)
User cannot edit
__Nzl4Diameter
=
0
0
0
Diameter of pickup nozzle (mm)
User cannot edit
__Nzl5Diameter
=
0
0
0
Diameter of pickup nozzle (mm)
User cannot edit
__Nzl6Diameter
=
0
0
0
Diameter of pickup nozzle (mm)
User cannot edit
__Nzl7Diameter
=
0
0
0
Diameter of pickup nozzle (mm)
User cannot edit
__Nzl8Diameter
=
0
0
0
Diameter of pickup nozzle (mm)
User cannot edit
__Nzl9Diameter
=
0
0
0
Diameter of pickup nozzle (mm)
User cannot edit
__Nzl10Diameter
=
0
0
0
Diameter of pickup nozzle (mm)
User cannot edit
__Nzl11Diameter
=
0
0
0
Diameter of pickup nozzle (mm)
User cannot edit
__Nzl12Diameter
=
0
0
0
Diameter of pickup nozzle (mm)
User cannot edit
_______GLASS_QF_VALUE______
=
0
0
0
__GlassQfLeadQty1
=
0
27
27
Number of leads per one side of glass gauge QF
User cannot edit
l
__GlassQfLeadWidth1
=
0
0.25
0.25
Glass gauge QF lead width
User cannot edit
l
__GlassQfLeadLen1
=
0
1.5
1.5
Glass gauge QF lead length
User cannot edit
l
__GlassQfPitch1
=
0
0.5
0.5
Glass gauge QF lead pitch
User cannot edit
l
__GlassQfDistance1
=
0
19
19
Glass gauge QF per one side length
User cannot edit
l
__GlassCircleDiameter1
=
0
2
2
Diameter of glass parts circle mark
User cannot edit
l
__GlassCircleDistance1
=
0
12.94
12.94
Distance between the center of glass circle marks
User cannot edit
l
__GlassCentCircleDiameter1
=
0
5.05
5.05
Diameter of glass gauge QF center circle
User cannot edit
l
__GlassQfLeadQty2
=
0
0
0
No. of leads per one side of glass gauge QF
User cannot edit
l
__GlassQfLeadWidth2
=
0
0
0
Glass gauge QF lead width
User cannot edit
l
__GlassQfLeadLen2
=
0
0
0
Glass gauge QF lead length
User cannot edit
l
__GlassQfPitch2
=
0
0
0
Glass gauge QF lead pitch
User cannot edit
l
__GlassQfDistance2
=
0
0
0
Glass gauge QF per one side length
User cannot edit
l
__GlassCircleDiameter2
=
0
0
0
Diameter of glass gauge QF center circle
User cannot edit
l
__GlassCircleDistance2
=
0
0
0
Distance between the center of glass circle marks
User cannot edit
l
__GlassCentCircleDiameter2
=
0
0
0
Diameter of glass gauge QF center circle
User cannot edit
l
__GlassLogicalLevel
=
0
-1500
-1500
Logical brightness level when the present glass parts is vision processed (-25500~25500) 0= impossible to carry out vision processing
User cannot edit
l
_____MATRIX_TABLE___
0
0
0
_MtxTblPitch
=
7
7
7
Mark Pitch (mm)
User cannot edit
_MtxTblX
=
65
65
65
Numbers of the measurement in the X direction
User cannot edit
_MtxTblY
=
45
45
45
Numbers of the measurement in the Y direction
User cannot edit
_MtxTblElegance
=
0.1
0.1
0.1
Elegance Value
User cannot edit
_MtxTblWaitTime1
=
30
30
30
Waiting time after servo movement completion [msec]
User cannot edit
_MtxTblWaitTime2
=
150
150
150
Waiting time for lamp to turn ON [msec]
User cannot edit
_______NOZZLE_TYPE______
=
0
0
0
_Nzl1Type
=
0
0
0
Nozzle type 0: Standard 1: Mechanical Chuck 2: Custom
User cannot edit
_Nzl2Type
=
0
0
0
Nozzle type 0: Standard 1: Mechanical Chuck 2: Custom
User cannot edit
_Nzl3Type
=
0
0
0
Nozzle type 0: Standard 1: Mechanical Chuck 2: Custom
User cannot edit
_Nzl4Type
=
0
0
0
Nozzle type 0: Standard 1: Mechanical Chuck 2: Custom
User cannot edit
_Nzl5Type
=
0
0
0
Nozzle type 0: Standard 1: Mechanical Chuck 2: Custom
User cannot edit
_Nzl6Type
=
0
0
0
Nozzle type 0: Standard 1: Mechanical Chuck 2: Custom
User cannot edit
_Nzl7Type
=
0
0
0
Nozzle type 0: Standard 1: Mechanical Chuck 2: Custom
User cannot edit
_Nzl8Type
=
0
0
0
Nozzle type 0: Standard 1: Mechanical Chuck 2: Custom
User cannot edit
_Nzl9Type
=
0
0
0
Nozzle type 0: Standard 1: Mechanical Chuck 2: Custom
User cannot edit
_Nzl10Type
=
0
0
0
Nozzle type 0: Standard 1: Mechanical Chuck 2: Custom
User cannot edit
_Nzl11Type
=
0
0
0
Nozzle type 0: Standard 1: Mechanical Chuck 2: Custom
User cannot edit
_Nzl12Type
=
0
0
0
Nozzle type 0: Standard 1: Mechanical Chuck 2: Custom
User cannot edit
____PICKUP_OFFSET_______
=
0
0
0
Z_Nzl1PickUpOfst
=
0
0
0
XP141 pickup offset Z for nozzle 1 (mm)
Calibrated data
Z_Nzl2PickUpOfst
=
0
0
0
XP141 pickup offset Z for nozzle 2 (mm)
Calibrated data
8/10

XP Proper Data List V1.40
14/11/2002
Item
XP141
XP241
XP341
Description
Reboot
Z_Nzl3PickUpOfst
=
0
0
0
XP141 pickup offset Z for nozzle 3 (mm)
Calibrated data
Z_Nzl4PickUpOfst
=
0
0
0
XP141 pickup offset Z for nozzle 4 (mm)
Calibrated data
Z_Nzl5PickUpOfst
=
0
0
0
XP141 pickup offset Z for nozzle 5 (mm)
Calibrated data
Z_Nzl6PickUpOfst
=
0
0
0
XP141 pickup offset Z for nozzle 6 (mm)
Calibrated data
Z_Nzl7PickUpOfst
=
0
0
0
XP141 pickup offset Z for nozzle 7 (mm)
Calibrated data
Z_Nzl8PickUpOfst
=
0
0
0
XP141 pickup offset Z for nozzle 8 (mm)
Calibrated data
Z_Nzl9PickUpOfst
=
0
0
0
XP141 pickup offset Z for nozzle 9 (mm)
Calibrated data
Z_Nzl10PickUpOfst
=
0
0
0
XP141 pickup offset Z for nozzle 10 (mm)
Calibrated data
Z_Nzl11PickUpOfst
=
0
0
0
XP141 pickup offset Z for nozzle 11 (mm)
Calibrated data
Z_Nzl12PickUpOfst
=
0
0
0
XP141 pickup offset Z for nozzle 12 (mm)
Calibrated data
__________BLACK_MASK_LEVEL___________
=
0
0
0
__BMLReturnRatio
=
100
100
100
Black mask brightness ratio. When the brightness is less than Black Mask Level, how much % of the Black mask is convert into brightness. (%). User cannot edit
__BMLSide1Nzl1
=
0
0
0
The nozzle Black Mask Level (Use this when the proper data "__BlackMaskLevel" is set to "-1". )
User cannot edit
__BMLSide1Nzl2
=
0
0
0
The nozzle Black Mask Level (Use this when the proper data "__BlackMaskLevel" is set to "-1". )
User cannot edit
__BMLSide1Nzl3
=
0
0
0
The nozzle Black Mask Level (Use this when the proper data "__BlackMaskLevel" is set to "-1". )
User cannot edit
__BMLSide1Nzl4
=
0
0
0
The nozzle Black Mask Level (Use this when the proper data "__BlackMaskLevel" is set to "-1". )
User cannot edit
__BMLSide1Nzl5
=
0
0
0
The nozzle Black Mask Level (Use this when the proper data "__BlackMaskLevel" is set to "-1". )
User cannot edit
__BMLSide1Nzl6
=
0
0
0
The nozzle Black Mask Level (Use this when the proper data "__BlackMaskLevel" is set to "-1". )
User cannot edit
__BMLSide1Nzl7
=
0
0
0
The nozzle Black Mask Level (Use this when the proper data "__BlackMaskLevel" is set to "-1". )
User cannot edit
__BMLSide1Nzl8
=
0
0
0
The nozzle Black Mask Level (Use this when the proper data "__BlackMaskLevel" is set to "-1". )
User cannot edit
__BMLSide1Nzl9
=
0
0
0
The nozzle Black Mask Level (Use this when the proper data "__BlackMaskLevel" is set to "-1". )
User cannot edit
__BMLSide1Nzl10
=
0
0
0
The nozzle Black Mask Level (Use this when the proper data "__BlackMaskLevel" is set to "-1". )
User cannot edit
__BMLSide1Nzl11
=
0
0
0
The nozzle Black Mask Level (Use this when the proper data "__BlackMaskLevel" is set to "-1". )
User cannot edit
__BMLSide1Nzl12
=
0
0
0
The nozzle Black Mask Level (Use this when the proper data "__BlackMaskLevel" is set to "-1". )
User cannot edit
__BMLSide2Nzl1
=
0
0
0
The nozzle Black Mask Level (Use this when the proper data "__BlackMaskLevel" is set to "-1". )
User cannot edit
__BMLSide2Nzl2
=
0
0
0
The nozzle Black Mask Level (Use this when the proper data "__BlackMaskLevel" is set to "-1". )
User cannot edit
__BMLSide2Nzl3
=
0
0
0
The nozzle Black Mask Level (Use this when the proper data "__BlackMaskLevel" is set to "-1". )
User cannot edit
__BMLSide2Nzl4
=
0
0
0
The nozzle Black Mask Level (Use this when the proper data "__BlackMaskLevel" is set to "-1". )
User cannot edit
__BMLSide2Nzl5
=
0
0
0
The nozzle Black Mask Level (Use this when the proper data "__BlackMaskLevel" is set to "-1". )
User cannot edit
__BMLSide2Nzl6
=
0
0
0
The nozzle Black Mask Level (Use this when the proper data "__BlackMaskLevel" is set to "-1". )
User cannot edit
__BMLSide2Nzl7
=
0
0
0
The nozzle Black Mask Level (Use this when the proper data "__BlackMaskLevel" is set to "-1". )
User cannot edit
__BMLSide2Nzl8
=
0
0
0
The nozzle Black Mask Level (Use this when the proper data "__BlackMaskLevel" is set to "-1". )
User cannot edit
__BMLSide2Nzl9
=
0
0
0
The nozzle Black Mask Level (Use this when the proper data "__BlackMaskLevel" is set to "-1". )
User cannot edit
__BMLSide2Nzl10
=
0
0
0
The nozzle Black Mask Level (Use this when the proper data "__BlackMaskLevel" is set to "-1". )
User cannot edit
__BMLSide2Nzl11
=
0
0
0
The nozzle Black Mask Level (Use this when the proper data "__BlackMaskLevel" is set to "-1". )
User cannot edit
__BMLSide2Nzl12
=
0
0
0
The nozzle Black Mask Level (Use this when the proper data "__BlackMaskLevel" is set to "-1". )
User cannot edit
__________OTHERS___________
=
0
0
0
X_MeasureFidMark
=
117.5
137.1
137.1
X-coordinates of major fiducial mark (Reference conveyor rail mark)
Calibrated data
Y_MeasureFidMark
=
209.05
207.75
211.75
Y-coordinates of major fiducial mark (Reference conveyor rail mark)
Calibrated data
__ConvWidthMtrSpeed
=
0.008
0.008
0.008
Conveyor width change speed [mm]/[msec]
Calibrated data
__ConvWidthOffset
=
0
0
0
Offset value of conveyor width when adjusting the conveyor width [mm]
Calibrated data
__ConvWidthMarkDiffX
=
0
-4.4
-4.4
Offset for difference in X-direction between reference mark and adjustable rail mark [mm]
Calibrated data
__ConvMainArrvStopDis
=
20
20
20
The distance of MAIN arrival check sensor to the stopper. [mm] (Inputting range 20 or grater)
User can edit
__DLLRatio
=
0
0
0
DLL multiply ratio when DLL value is auto-calibrated (in a case 0, it is 0.63)
User cannot edit
__VT231LLRatio
=
0
0
0
Fine adjust the LL level during processing VisionType=231(White BGA) [Range 0, 0.7 - 2.0] [T1.12c]
User cannot edit
X_CoplanarityPosX
=
0
0
0
Coplanarity check position X
User cannot edit
Y_CoplanarityPosY
=
0
0
0
Coplanarity check position Y
User cannot edit
Z_CoplanarityPosZ
=
0
0
0
Coplanarity check position Z
User cannot edit
__CoplaCamShutterSpeed
=
0
0
0
Coplanarity camera shutter speed setting (µs) *Also, change the camera SW setting
User cannot edit
__MarkAreaTolerance
=
0
0
0
Tolerance of F-mark reading area (mm)
User can edit
__MarkPitchTolerance
=
0
0
0
Tolerance of F-mark read pitch (mm)
User can edit
__DesEndDistanceFromDownEnd
=
0
0
0
Not used at present
User cannot edit
__PickPosMeasureOfstX1
=
-0.1
0
0
Enter the difference of the mark camera pickup offset and actual pickup offset at the pickup position measurement.
User can edit
__PickPosMeasureOfstY1
=
-0.05
0
0
Enter the difference of the mark camera pickup offset and actual pickup offset at the pickup position measurement.
User can edit
9/10