xp141-241-341-5.0E.pdf - 第36页
FK-9F98- 29 XP Series Training Text for Service Engineers Edition 5.0 XP141 – Chapter 4 Loader Adjustment Page 11 of 12 Fuji Machine Mfg. Co., Ltd. Okazaki. SMT Equipment Quality Assurance Dept. 4 – 11 CS Section 4. 10 C…

FK-9F98-29 XP Series Training Text for Service Engineers
Edition 5.0 XP141 – Chapter 4 Loader Adjustment Page 10 of 12
Fuji Machine Mfg. Co., Ltd. Okazaki.
SMT Equipment Quality Assurance Dept.
4 – 10 CS Section
4.9 Board Sensors Adjustment
1. For each board sensor adjustment, use a FUJI96 board.
2. Set the sensor dial to its maximum volume (to clockwise).
Note: Ensure that when the sensor volume is at the maximum it does not detect any part
of the X and Y-axes moving above it. If the X or Y-axes affect the sensor, reduce the
sensor volume.
To ensure that there is enough clearance between the board and sensors, adjust the
distance between the board underside and the sensor top surface to the following
distances:
1. In-lifter board arrival sensor................................ X01B InStArrvChk
2. Main conveyor board deceleration sensor ......... X01C MainStDecelPnt
3. Main conveyor board arrival sensor.................... X01D MainStArrvChk
4. Main conveyor board pass sensor...................... X022 MainStPassChk
5. Out conveyor board pass sensor........................ X020 OutStPassChk
In- lifter board arrival sensor ............................27mm
Main conveyor board deceleration sensor.........25.5mm
Main conveyor board arrival sensor ................ 25.5mm
Main conveyor board pass sensor ...................30mm
Out conveyor board pass sensor ......................25.5mm
Board
Sensor
40mm
In-lifter
1
2 3
4
5mm
60mm
36mm
Main lifter
5
Out-conveyor

FK-9F98-29 XP Series Training Text for Service Engineers
Edition 5.0 XP141 – Chapter 4 Loader Adjustment Page 11 of 12
Fuji Machine Mfg. Co., Ltd. Okazaki.
SMT Equipment Quality Assurance Dept.
4 – 11 CS Section
4. 10 Conveyor Width and Movement
• Measuring tool: Calipers (0.05mm)
1. Ensure that the width change can be carried out smoothly, when the conveyor is moved
to its Min. (50mm or less) ~ Max. (356mm or greater) width.
Note: Do not use the conveyor auto width changer, as this is not adjusted yet.
2. Set the entrance of the In-conveyor to 130mm. Check a few points along the conveyor
width from entrance to exit. The difference between the maximum width and minimum
width should be within 0.5mm. If it is out of the tolerance, please contact FUJI.
3. The speed of board loading and the speed of the conveyor width changer are set at FUJI
prior to machine shipment. Changing these speeds is not recommended. However for
your reference the location and function of the conveyor speed controllers are given
below:
Loading Function Controller
Board Loading (Normal speed) T1VR1
Board Loading (Deceleration) T1SP1
Conveyor width change T1SP2
T1SP1 T1SP2
Side1; Back of
the right door of
the bottom Box.
T1VR1
Side1: Rear of the
Electric Box, top
left connector on
the main relay
board.
Main relay
board
Speed control
board cover
Electric Box Door

FK-9F98-29 XP Series Training Text for Service Engineers
Edition 5.0 XP141 – Chapter 4 Loader Adjustment Page 12 of 12
Fuji Machine Mfg. Co., Ltd. Okazaki.
SMT Equipment Quality Assurance Dept.
4 – 12 CS Section
NOTES: