Infinity EX Camera System Module.pdf - 第31页

INFINITY EX CAME RA SYSTE M MODULE ADJUS TMENT S AND SET TINGS Chapter Issue 3 J an 04 Technical Reference Manual 17.31 26. Select Ex it tw ice. 27. On completion, ca rry out Calibrate V ision and Calibrate Offset Calibr…

100%1 / 54
INFINITY
EX
CAMERA SYSTEM MODULE
ADJUSTMENTS AND SETTINGS
17.30 Technical Reference Manual Chapter Issue 3 Jan 04
substantially thicker board clamps used to accomodate the carrier.
CAUTION
RESTORE DEFAULT HEIGHTS. Ensure Restore Default Heights is not
selected otherwise the camera board stop may foul the token carrier.
1. From the Run menu, select Setup.
2. Select Load Data.
3. From the Load Data window highlight DTVPOR product file and select
Load.
4. Select Edit Data.
5. From the Edit Current Data Process Parameters window, ensure Board
Thickness is set to 0.2mm.
6. Ensure the correct stencil is loaded to the machine.
7. From the Run menu, select Maint.
8. Select Diagnost.
9. From the Module Diagnostic page, select Rising Table.
10.Manually load the carrier (with tokens loaded), ensuring the carrier is at the
centre of the board clamps.
11.Select Raise Table to Vision Height.
12.Press the E Stop button.
13.Manually move the camera over the tooling area ensuring there is adequate
clearance between the camera, carrier and board clamps.
14.Press the System button.
15.Select Drive Table using Jog Buttons and drive the table ensuring adequate
clearance between the camera board stop and the token carrier. (This is to
prevent camera damage when the machine is re-initialized in Step 18.)
16.Select Set Reference Vision Height. The message ‘This Will Alter The
Printer Configuration File - Please Confirm’ is displayed.
17.Select Home Rising Table and remove the carrier.
18.Re-intialize the machine.
19.Select Diagnost.
20.Select Raise Table to Vision Height.
21.Place the carrier on the rails, adjusting its position so that the number 1
fiducial is displayed on the MMI.
22.Select Drive Table Using Jog Buttons until the board fiducial is in focus.
NOTE
With the rising table in this position ensure that both rails are lifted clear of
the clatter bars.
23.Select Set Reference Vision Height. The message ‘This Will Alter The
Printer Configuration File - Please Confirm’ is displayed.
24.Select Confirm.
25.Select Home Rising Table.
INFINITY
EX
CAMERA SYSTEM MODULE
ADJUSTMENTS AND SETTINGS
Chapter Issue 3 Jan 04 Technical Reference Manual 17.31
26.Select Exit twice.
27.On completion, carry out Calibrate Vision and Calibrate Offset Calibrations.
Refer to the Calibration section of this chapter.
Camera Focus The camera focus is factory set and sealed and should not be adjusted.
Camera Reference
Position
1. In Camera Axes Diagnostics, select Home Camera X Axis and press Run
Diagnost button.
2. Select Home Camera Y Axis and press Run Diagnost button.
3. Select Initialize Vision System and press Run Diagnost button.
4. Select Drive to Reference Position and press Run Diagnost button, a box
and the white dot on the board clamp is visible on the monitor.
5. Using Move Camera X Axis Using Jog Buttons and Move Camera Y Axis
Using Jog Buttons, position the box centrally inside the white dot, as shown.
6. Select Set Reference Position and press Run Diagnost button.
7. The message ‘This Will Alter The Printer Configuration File - Please
Confirm’ is displayed.
8. Select Confirm. The message ‘Printer Configuration Data File Saved’ is
displayed.
Setting Camera
Type
1. Turn the mains isolator to ON. On completion of autologin, minimize the
DEK printer program.
2. Using the mouse control, click on the Start icon in the desktop taskbar. The
Monitor
Board Clamp
Box
White Dot
INFINITY
EX
CAMERA SYSTEM MODULE
ADJUSTMENTS AND SETTINGS
17.32 Technical Reference Manual Chapter Issue 3 Jan 04
Start menu is displayed:
3. Click on Run. The following window is displayed:
4. Click in the open box, type d:/Program Files/Dek/MachineControl/
Printer/PostGhost.exe. Click OK the following window is displayed: