00191174-01.pdf - 第22页

1 General Functions User’s Manual Test P rogram SITEST 1.6 "Miscellaneous" Menu Software Version 10.xx Edition 03/98 1 - 10 1.6.2 Run Parameters ● If you wish the operati on parame ters of the tu rning sta tion…

100%1 / 88
User’s Manual Test Program SITEST 1 General Functions
Software Version 10.xx Edition 03/98 1.6 "Miscellaneous" Menu
1 - 9
1.6.1 Options
Different options can be activated, or deactivated, with the aid of the functions of the "Options" submenu.
From the "Miscellaneous" menu select the
Options
option and press the RETURN key.
The "Options" menu is displayed on the screen.
Overview of the Functions:
-
Change to step mode to turn the cycle mode on/off
-
Display nozzle/digit to switch from the "Teach display with camera and nozzle position" to
"Teach display with camera position in
µ
m and digits" and vice versa
-
Use Com display to turn the command display on/off
-
Switch MD-printer to turn the MC-printer on/off
-
KBD-Buffer to turn the keyboard buffer on/off
-
Display MC IO to turn the MC-display "IO" on/off
-
Display MC axis to turn the MC-display "axis" on/off
-
Display MC sequence to turn the MC-display "sequence" on/off
Select the desired function and press the RETURN key.
The selected function is executed.
Press the ESC key twice to return to the SITEST main menu.
Miscellaneous
Options
Display files
Version description
Clear screen
Display file
Configuration
Operation parameter
Machine-Config.
Change to step mode
Display nozzle/digit
Use Com display
Switch MD-printer
KBD-Buffer
Display MC IO
Display MC axis
Display MC sequence
Options
1 General Functions User’s Manual Test Program SITEST
1.6 "Miscellaneous" Menu Software Version 10.xx Edition 03/98
1 - 10
1.6.2 Run Parameters
If you wish the operation parameters of the turning stations or the operation parameters for picking up and
placing to be displayed, select the menu option
Operation parameter
from the "Miscellaneous" menu and
press the RETURN key.
The "Operation parameter" menu is displayed on the screen.
Overview of the Functions:
-
dp1/dp2 to display and edit, if required, the operation parameters "ref. point" and
"distance" for the turning stations dp1 and dp2
-
Pick-up/placement to display and edit, if required, the operation parameters "Distance", "Force",
"Speed", "Acceleration", "Deceleration" and "Positioning mode"
From the "Operation parameter" menu select the appropriate function to cause the operation parameters
required by you to be displayed, and press the RETURN key.
The input menu is opened. It displays the operation parameters of the selected function which can be edi-
ted, if desired.
1.6.3 Machine Configuration
If you wish to set specific machine options, select the
Machine-Config.
option from the "Miscellaneous"
menu and press the RETURN key.
The "Machine-Config." menu is displayed on the screen.
Miscellaneous
Options
Display files
Version description
Clear screen
Display file
Configuration
Operation parameter
Machine-Config.
dp1/dp2
Pick-up/placement
Operation parameter
Miscellaneous
Options
Display files
Version description
Clear screen
Dispaly file
Configuration
Operation parameter
Machine-Config.
Type of conveyor
Transport mode
Ceramic s. centering
4x5 IC-Noz. Changer
Machine-Config.
User’s Manual Test Program SITEST 1 General Functions
Software Version 10.xx Edition 03/98 1.6 "Miscellaneous" Menu
1 - 11
Overview of the Functions:
-
Type of conveyor Menu for selecting the current conveyor type (e.g. left conveyor)
-
Transport mode Menu for selecting the range of PCB lengths for PCBs that are to be processed on
the machine
-
Ceramic s. centering Menu for selecting the type of ceramic substrate centering
-
4x5 IC-Noz. Changer To set the default values for the 4x5 IC nozzle changer
To determine the currently installed conveyor, select the
Type of conveyor
menu option from the
"Machine-Config." menu and actuate the RETURN key.
The "Type of conveyor" menu is displayed on the screen.
Overview of the Functions:
-
Right conveyor The fixed side of the conveyor, including calibration piece pocket and integrated
measuring hole for the MA zero point, is located on the right (viewing in the
direction of PCB travel).
Left conveyor The fixed side of the conveyor, including calibration piece pocket and integrated
measuring hole for the MA zero point, is located on the left (viewing in the direc-
tion of PCB travel).
-
Standard conveyor The fixed side of the conveyor including calibration piece pocket is located on the
right (viewing in the direction of PCB travel). The measuring hole for the MA zero
point is integrated in the setting gauge. (The setting gauge is placed on the ele-
vating table).
Select the type of conveyor installed in the machine and actuate the RETURN key. The selected conveyor
type is displayed on the screen.
NOTES
By selecting the conveyor type you also define for subsequent calibration operations to be performed
where the calibration piece pocket, the MA zero point or the PCB reference corner is located.
The selection of the conveyor type is to be carried out once upon the intital start-up, prior to the perfor-
mance of calibration. transport and mapping functions, or whenever the conveyor and/or the calibration
piece pocket are modified or newly installed.
If a new conveyor type was selected and stored, the positions of the MA zero point, the calibration piece
and the PCB reference corner must be recalibrated because they were assigned default values.
Actuate the ESC key to return to the "Machine-Config." menu.
Miscellaneous
Options
Display files
Version description
Clear screen
Dispaly file
Configuration
Operation parameter
Machine-Config.
Type of conveyor
Transport mode
Ceramic s. centering
4x5 IC-Noz. Changer
Machine-Config.
Right conveyor
Left conveyor
Standard conveyor
Type of conveyor