00191174-01.pdf - 第77页
User’s Manual Test Program S ITEST 4 Mapping Software Version 10.xx Edition 03/98 4.1 Preparatory Steps for the Mapping Operation 4 - 1 4 Mapping WARNING ∆ ! ∆ ! The gan tries will be movin g during the perfo rmance o f …

User’s Manual Test Program SITEST
Software Version 10.xx Edition 03/98
4 - II

User’s Manual Test Program SITEST 4 Mapping
Software Version 10.xx Edition 03/98 4.1 Preparatory Steps for the Mapping Operation
4 - 1
4 Mapping
WARNING
∆
!
∆
!
The gantries will be moving during the performance of the function described in this section. Prior to the exe-
cution of this function make sure that neither any part of your body nor any objects are in the traversing range
of the gantries - DANGER OF INJURY.
Functions of the different types of mapping
PCB Mapping:
In PCB mapping, the gantry position is measured in relation to a high-precision glass plate. The data thus
determined are stored and used by the station software for the corrrection of the X and Y-coordinates.
RV Mapping:
Owing to the gantry offset, the PCB - RV camera offset (X- and Y-distance between the camera and the
revolver head) depends on the gantry position. RV mapping is designed to determine any change of the
PCB-RV- camera offset at the respective measuring points of the glass plate. The data thus determined are
stored for use by the station software.
IC Mapping:
Owing to the gantry offset, the RV camera - IC tube offset (X- and Y-distance between the camera and the
tube) depends on the gantry position. IC mapping is designed to determine any change of the RV camera - IC
tube offset at the respective measuring points of the glass plate. The data thus determined are stored for use
by the station software.
4.1 Preparatory Steps for the Mapping Operation
●
Using the "RV-Head ref. run", "IC-head refer. run" and "Gantry refer. run" menu functions have the gantries
approach their reference positions.
●
Select the Select gantry option (applies to SIPLACE 80S only) and press the RETURN key.
The "Select gantry" menu opens.
●
Select the gantry 1 active menu option for gantry 1 and press the RETURN key.
●
Press the ESC key to return to the SITEST main menu.
●
Select the Functions menu option and press the RETURN key.
The "Functions" menu opens.
●
Select the Width adjustment menu option and press the RETURN key.
The "Width adjustment" menu opens.
●
Adjust the width of the PCB conveyor to the width of the mapping plate using the functions of the "Width
adjustment" menu.
●
Press the ESC key to return to the "Functions" menu.
●
Select the Conveyor menu option and press the RETURN key.
The "Conveyor" menu opens.
●
Manually slide the PCB stopper to the center of the conveyor width.
●
Select the PCB Stopper function to extend the stopper and press the RETURN key.
The stopper is extended.

4 Mapping User’s Manual Test Program SITEST
4.1 Preparatory Steps for the Mapping Operation Software Version 10.xx Edition 03/98
4 - 2
●
Slide the mapping plate onto the center conveyor.
NOTE
For the RV- and IC-mapping a mapping plate with a dark, dull surface must be used.
CAUTION
∆
!
On no account
must the PCB clamping mechanism be actuated during PCB mapping
. If the mapping
plate for PCB mapping is clamped, it may be damaged so severely that it cannot be used any more.
●
For RV-mapping and IC-mapping select the
PCB clamping
function from the "Conveyor" menu to clamp
the mapping plate and press the RETURN key.
●
Press the ESC key twice to return to the SITEST main menu.
4.1.1 PCB Mapping
NOTE
Verify that the calibration data for the component camera, the PCB camera, PCB/component camera offset
and the MA-zero point have already been determined.
●
From the main menu select the
Mapping
option and press the RETURN key.
The "Mapping" menu is displayed on the screen.
Overview of the Functions:
-
Mapping mode Menu for the selection of the mapping resolution
-
PCB-mapping Menu for the mapping run with PCB camera
-
RV-mapping Menu for the mapping run with the RV-head
-
IC-mapping Menu for the IC-mapping run with the IC-head
-
Read mapping file to read in the mapping data file
Mapping
Mapping mode
PCB-mapping
RV-mapping
IC-mapping
Read mapping file