3 Calibration Functions User’s Manual Test P rogram SITEST 3.11 Calibration of t he Nozzle Changer Software Version 10.xx Edition 03/98 3 - 20 ● Press the "EME RGENCY S TOP" but ton and open the protect ive cov…

User’s Manual Test Program SITEST 3 Calibration Functions
Software Version 10.xx Edition 03/98 3.10 Calibration of the Coplanarity Laser Module (SIPLACE 80F)
3 - 19
3.10 Calibration of the Coplanarity Laser Module
(SIPLACE 80F)
NOTE
Prior to the calibration of the coplanarity module, all calibration operations described earlier in this chapter
must have been performed.
●
Carry out the preparatory steps proceeding as described in section 3.1.
●
Pick up nozzle no. 417 with the IC-head.
●
From the main menu select the Functions option and press the RETURN key.
The "Functions" menu is now displayed on the screen.
●
From this menu select the Coplanarity function option and press the RETURN key. The "Coplanarity
function" menu opens.
Overview of the Functions:
-
Testing to perform the functional test
-
Measure laser pos.xy to determine the position of the laser module in x and y-directions (center of laser
focal point)
-
Measure focus height to measure the focal point (z-position)
-
Measure z-Delta to calculate the z-height delta from the component camera top edge to laser module
-
Read version to display the version number of the laser module
-
Move to laser pos. to approach the laser position (center of laser focus)
-
Move to park pos. to approach the park position
-
Positions to display the laser positions (x, y, z-starting positions, z-step size)
●
Select the Positions menu item and press the RETURN key.
The input menu for the x, y, z-positions opens.
●
Enter the starting positions into the input menu.
●
After the last entry, press the RETURN key to accept the values entered.
●
Press the ESC key to exit from the input menu.
●
Select the Move to laser pos. menu item and press the RETURN key.
The active gantry moves the nozzle over the coplanarity module.
Functions
Conveyor
CRDL tester
Component-table
Nozzle changer
Coplanarity function
Movable conv. side
Width adjustment
Testing
Measure laser pos.xy
Measure focus height
Measure z-Delta
Read version
Move to laser pos.
Move to park pos.
Positions
Coplanarity function

3 Calibration Functions User’s Manual Test Program SITEST
3.11 Calibration of the Nozzle Changer Software Version 10.xx Edition 03/98
3 - 20
●
Press the "EMERGENCY STOP" button and open the protective cover.
●
Attach the calibration piece so that it is on the nozzle in centered position.
●
Carefully push the z-axis down onto the coplanarity module.
NOTE
The calibration piece must be in alignment with the eye of the laser. If this is not the case, correct the
positional values in the "Positions" input value and reapproach the coplanarity module as described
above.
●
Close the protective cover and turn on the control.
●
From the "Coplanarity function" menu select the
Testing
option and press the RETURN key. The z-axis
moves to the "z-start position". The height of the calibration piece is measured.
●
From the menu select the
Measure focus height
function and press the RETURN key.
The focus height is measured.
●
From the menu select the
Measure laser pos.xy
function and press the RETURN key.
The x and y-positions of the laser module are determined.
●
From the menu select the
Measure z-Delta
function and press the RETURN key.
The height of the focal point is measured in relation to the conveyor top edge.
●
Press the ESC key twice to return to the SITEST main menu.
3.11 Calibration of the Nozzle Changer
The selection menu for the nozzle changer to be calibrated can be opened with the aid of the "Nozzle Changer"
menu option on the "Functions" menu.
NOTE
Verify beforehand that the calibration data for the PCB camera, component/PCB camera
offset and machine zero point have already been determined.
●
From the main menu select the
Functions
option and press the RETURN key.
The "Functions" menu is now displayed on the screen.

User’s Manual Test Program SITEST 3 Calibration Functions
Software Version 10.xx Edition 03/98 3.11 Calibration of the Nozzle Changer
3 - 21
●
From this menu select the
Nozzle changer
option and press the RETURN key.
The "Nozzle changer" selection menu opens.
Overview of the Functions:
-
Noz.changer RV-head Menu for the calibration of the RV-nozzle changer
-
Noz.changer IC-head Menu for the calibration of the IC-nozzle changer
3.11.1 Calibration of the RV-Nozzle Changer
●
To calibrate the RV-nozzle changer, select the
Noz.changer RV-head
option from the "Nozzle changer"
menu and press the RETURN key.
The "Noz.changer RV-head" menu is displayed on the screen.
Overview of the Functions:
-
Cal.noz.chang.compl. to determine the x and y-values for all magazines
-
Calibrate magazine to calibrate a single magazine
-
Pick up nozzle to pick up a nozzle from the selected garage (magazine compartment)
-
Return nozzle to deposit the nozzle in the selected garage (determination of the nozzle garage
height)
-
Step star axis to cycle the "star" axis
-
Garage [1 .. 12] to open the input field for the garage number
-
Magazine [1 .. 7] to open the input field for the magazine number
-
Disp. nozzle positions to display the values determined for each garage of the selected magazine
-
Reject nozzle to position the nozzle over the reject box and to discard the nozzle by pressing the
RETURN key (determination of the reject position)
Functions
Conveyor
CRDL tester
Component-table
Nozzle changer
Coplanarity function
Width adjustment
Movable conv. side
Coplanarity function
Noz.changer RV-head
Noz.changer IC-head
Nozzle changer
Functions
Conveyor
CRDL tester
Component-table
Nozzle changer
Coplanarity function
Width adjustment
Movable conv. side
Noz.changer rev.head
Noz.changer IC-head
Nozzle changer
Cal.noz.chang.compl.
Calibrate magazine
Pick up nozzle
Return nozzle
Step star axis
Garage [1..12]
Magazine [1..7]
Disp. nozzle position
Reject nozzle
Noz.changer RV-head