00191174-01.pdf - 第42页
2 Functions for the A djustment of the Machine User’s Manual Test Program S ITEST 2.4 Vacuum Board Software Version 10.xx Edition 03/98 2 - 14 2.3.5 Determination of the Position of the Movable Conveyor Side To determi n…

User’s Manual Test Program SITEST 2 Functions for the Adjustment of the Machine
Software Version 10.xx Edition 03/98 2.3 Functions
2 - 13
2.3.4 Width Adjustment
NOTE
The functions of the "Width adjustment" menu are only available if gantry 1 is "active".
●
From the "Functions" menu select the
Width adjustment
option and press the RETURN key. The "Width
adjustment" menu is displayed on the screen.
NOTE
During the performance of all functions of the width adjustment system, the elevating table must be in the
lowered
position.
Overview of the Functions:
-
Decrease width slow to adjust the conveyor width in small increments
-
Increase width slow to adjust the conveyor width in small increments
-
Decrease width fast to adjust the conveyor width in large increments
-
Increase width fast to adjust the conveyor width in large increments
-
Calibrate width adj. Determination of the reference conveyor width using a PCB that is exactly
100 mm in width (required for automatic width adjustment).
●
From the "Width adjustment" menu select the desired function, and press the RETURN key.
The function is now executed on the current conveyor.
NOTE
The value of the gantry position determined can be saved using the main menu option
File Manager
-->
Store MA-file
(see section 1.3).
●
Press the ESC key to return to the "Functions" menu.
Functions
Conveyor
CRDL
Component-table
Nozzle changer
Coplanarity function
Movable conv. side
Width adjustment
Decrease width slow
Increase width slow
Decrease width fast
Increase width fast
Calibrate width adj.
Width adjustment

2 Functions for the Adjustment of the Machine User’s Manual Test Program SITEST
2.4 Vacuum Board Software Version 10.xx Edition 03/98
2 - 14
2.3.5 Determination of the Position of the Movable Conveyor Side
To determine the current conveyor width, the position of the movable conveyor side is to be approached.
NOTE
The execution of the "Movable conv. side" function is only possible with gantry 1.
●
Adjust the conveyor width to that of the 100 mm wide PCB.
●
From the "Functions" menu select the
Movable conv. side
function and press the RETURN key.
The position of the movable conveyor side is determined and the result is displayed in the lower left corner
of the screen, and will be stored in the "MA-DATE-file.
●
Press the ESC key twice to return to the SITEST main menu.
2.4 Vacuum Board
The functions of this menu permit all required vacuum checks to be performed.
●
From the main menu select the "Vacuum" option and press the RETURN key
.
The "Vacuum" menu is displayed on the screen.
Overview of the Functions:
-
Measure vac.placement to measure the vacuum in the pick-up circuit and display the value
-
Measure vac. reject to measure the vacuum in the rejecting circuit and display the value
-
Turn screwdriver 1 one-time actuation of the screwdriver in the pick-up station
(no display).
-
Turn screwdriver 2 one-time actuation of the screwdriver in the rejecting station
(no display).
-
Step star axis to cycle the revolver head by one segment
-
Measure all vacuum to measure all vacuum values (pick-up and reject circuits) for all segments
-
Show vacuum results to display the measured vacuum values
Vacuum
Measure vac.placement
Measure vac. reject
Turn screwdriver 1
Turn screwdriver 2
Step star axis
Measure all vacuum
Show vacuum results
Print vacuum results
Alternate IC-vacuum
Alternate IC air-blow
Measure IC vacuum

User’s Manual Test Program SITEST 2 Functions for the Adjustment of the Machine
Software Version 10.xx Edition 03/98 2.5 Continuous Run
2 - 15
-
Print vacuum results to print the measured vacuum values
-
Alternate IC-vacuum to switch the vacuum for the IC-head on/off
-
Alternate IC air blow to switch the "blow air" supply for the IC-head on/off
-
Measure IC vacuum to measure the vacuum values of the IC-head
●
From the "Vacuum" menu select the desired function and press the RETURN key
.
The selected function is executed.
●
Press the ESC key to exit from the "Vacuum" menu.
2.5 Continuous Run
This function is designed to perform a complete head test.
NOTE
Prior to starting the continuous run, the respective placement head must have been submitted to a reference
run and the gantry must be so positioned that upon lowering the z-axis the sleeve will either make contact with
the conveyor top edge or a PCB located in the center conveyor.
●
From the main menu select the Continuous run option and press the RETURN key.
The "Continuous run" menu is displayed on the screen.
Overview of the Functions:
-
Ct.run RV-head to perform a continuous run of the RV-head
-
Cont.run IC-head to perform a continuous run of the IC-head
-
Ct.r. FORCE RV-head to open the start menu for the "RV-head" endurance run
-
Ct.r. FORCE IC-head to open the start menu for the "IC-head" endurance run
Continuous run
Ct.run RV-head
Cont.run IC-head
Ct.r. FORCE RV-head
Ct.r. FORCE IC-head