User’s Manual Test Program S ITEST 4 Mapping Software Version 10.xx Edition 03/98 4.1 Preparatory Steps for the Mapping Operation 4 - 7 NOTE On SIPL ACE 80S m achi nes it is good pr actice to select the Mapp. both gantri…

4 Mapping User’s Manual Test Program SITEST
4.1 Preparatory Steps for the Mapping Operation Software Version 10.xx Edition 03/98
4 - 6
4.1.2 RV-Mapping
NOTE
Prior to the performance of RV-mapping make sure that PCB mapping has already been carried out.
The SITEST program must not have been restarted following PCB mapping.
●
Carry out the preparatory steps as described in section 4.1.
Additional prerequisites are:
-
both gantries must be in the park position.
-
segment offset
I
and
PCB/component camera offset must already have been determined for both
gantries.
-
the calibration piece must be in the calibration piece pocket.
-
the calibration piece position must already have been determined.
-
on segment 1 of each revolver head a size 617 nozzle must be attached.
●
From the main menu select the
Mapping
option and press the RETURN key.
The "Mapping" menu is displayed on the screen.
●
Select the
RV-mapping
function and press the RETURN key.
The "RV-mapping" menu is displayed on the screen.
Overview of the Functions:
-
RV-mapping to perform the RV-mapping
-
Cont. RV-mapping to perform mapping in the continuous run mode until the continuous run is aborted
by pressing ESC
Display mapping data to display the mapping data determined
-
Mapping data ct. run to display the data determined in the continuous mapping run
-
Continue RV-mapping to continue mapping from the measuring point entered
-
Mapp. both gantries to perform the mapping run for both gantries of SIPLACE 80S
(MC-changeover is carried out automatically. The mapping run is first performed
for gantry 1, thereafter for gantry 2.)
●
From the "RV-mapping" menu select the
RV-mapping
function and press the RETURN key. The active
gantry performs the mapping run. The measured values are automatically stored after the completion of
this mapping run.
Mapping
Mapping mode
PCB-mapping
RV-mapping
IC-mapping
Read mapping file
RV-mapping
RV-mapping
Cont. RV-mapping
Display mapping data
Mapping data ct. run
Continue RV-mapping
Mapp. both gantries

User’s Manual Test Program SITEST 4 Mapping
Software Version 10.xx Edition 03/98 4.1 Preparatory Steps for the Mapping Operation
4 - 7
NOTE
On SIPLACE 80S machines it is good practice to select the
Mapp. both gantries
function instead of the
RV-
mapping
function so that the mapping run is performed for both gantries without
having to switch from gantry
1 to gantry 2 (Select gantry). When the mapping run of gantry 1 is completed, gantry 1 is automatically moved
to the park position, and subsequently the mapping run for gantry 2 is performed.
●
Press the ESC key twice to return to the SITEST main menu.
NOTE
The procedure described below is only required if on a SIPLACE 80S the RV-mapping procedure is per-
formed by means of the
RV-mapping
function
rather than the
Mapp. both gantries
function.
CAUTION
∆
!
Move gantry 1 to the park position using the menu functions of the "Gantry positions" menu (see
section 3.5).
●
Select the
Select gantry
menu option and press the RETURN key.
The "Select gantry" menu opens.
●
Select the
gantry 2 active
menu option for gantry 2 and press the RETURN key.
●
Press the ESC key to return to the SITEST main menu.
●
From the main menu select the
Mapping
option and press the RETURN key.
The "Mapping" menu is displayed on the screen.
●
Select the
RV-mapping
function and press the RETURN key.
The "RV-mapping" menu is displayed on the screen.
●
From the "RV-mapping" menu select the
RV-mapping
function and press the RETURN key. The active
gantry performs the mapping run. The measured values are automatically stored after the completion of
this mapping run.
●
Press the ESC key twice to return to the SITEST main menu.

4 Mapping User’s Manual Test Program SITEST
4.1 Preparatory Steps for the Mapping Operation Software Version 10.xx Edition 03/98
4 - 8
4.1.3 IC-Mapping
NOTE
Prior to the performance of IC-mapping make sure that PCB mapping has already been carried out.
The SITEST program must not have been restarted following PCB mapping.
●
Carry out the preparatory steps as described in section 4.1.
Additional prerequisites are:
-
PCB/component camera offset must already have been determined.
-
The calibration piece must be in the calibration piece pocket.
-
The calibration piece position must already have been determined.
-
The IC-camera must be completely calibrated.
-
On the IC-head a size 416 or 417 nozzle must be attached.
●
From the main menu select the
Mapping
option and press the RETURN key.
The "Mapping" menu is displayed on the screen.
●
Select the
IC-mapping
function and press the RETURN key.
The "IC-mapping" menu is displayed on the screen.
Overview of the Functions:
-
IC-mapping to perform IC-mapping
-
Cont.IC-mapping to perform mapping in a continuous run until the continuous run is aborted by
pressing ESC
-
Display mapping data to display the mapping data determined
-
Mapping data ct. run to display the data determined in the continuous mapping run
-
Continue IC-mapping to continue mapping from the measuring point entered onwards
●
From the "IC-mapping" menu select the
IC-mapping
function and press the RETURN key. The gantry
performs the mapping run. The measured values are automatically stored after the completion of the
mapping run.
●
Press the ESC key twice to return to the SITEST main menu.
Mapping
Select conv. side
Mapping mode
PCB-mapping
RV-mapping
IC-mapping
IC-mapping
IC-mapping
Cont.IC-mapping
Display mapping data
Mapping data ct. run
Continue IC-mapping