100%1 / 88
User’s Manual Test Program SITEST 3 Calibration Functions
Software Version 10.xx Edition 03/98 3.8 Calibration of the IC-Camera (SIPLACE 80F)
3 - 15
3.8.1 Changing the Illumination Values
NOTE
As a rule, changing the illumination values is not
required. Any change in the values performed in a non-expert
manner will result in incorrect calibration results.
From the "IC-camera "menu select the
Illumination values
option and press the RETURN key.
The "Illumination values" input menu is displayed on the screen.
Overview of the Functions:
-
Illumination steep steep angle of illumination
-
Illumination middle medium angle of illumination
-
Illumination flat flat angle of illumination
Change the values as required and confirm your entries by pressing the RETURN key.
Exit from the input menu by pressing the ESC key.
Repeat the calibration of the IC-camera as described in section 3.8.
Pos.calibration tool
Adopt current pos.
Teach position
PCB-camera
Component camera
IC-camera
Flip-chip-camera
Vision system
IC-camera
Move to by pcb-cam.
Move to by IC-head
IC-ca.pos & offset
Calibrate IC-camera
Illumination test
Illumination for GF
Meas.focus camera
Illumination values
Calibration factors
Camera number
Illumination values
Illumination steep
Illumination middle
Illumination flat
3 Calibration Functions User’s Manual Test Program SITEST
3.8 Calibration of the IC-Camera (SIPLACE 80F) Software Version 10.xx Edition 03/98
3 - 16
3.8.2 Measuring the Offset From IC-Head to Component Camera and
IC-Camera Position
NOTE
Verify that the calibration data for the PCB camera, IC-camera and PCB/component camera offset have
already been determined.
Carry out the preparatory steps proceeding as described in section 3.1 and section 3.1.1.
From the "Vision system" menu select the
IC-camera
option and press the RETURN key. The "IC-camera"
menu is displayed on the screen.
From the "IC-camera" menu select the
IC-ca.pos & offset
function and press the
RETURN key. The "IC-ca.pos & offset" menu is displayed on the screen.
Overview of the Functions:
-
Camera position to display or enter the x and y-position of the IC-camera
-
IC-Camera Offset to display or enter the x and y-offset of IC-head to component camera
-
Measure to determine the offset between IC-head and component camera in x and
y-directions and to determine the IC-camera position
From the "IC-ca.pos & offset" menu select the
Measure
function and press the RETURN key.
The offset between IC-head and component camera and the position of the IC-camera is measured.
NOTE
Following the completion of the measuring operation the values determined can be displayed on the
screen using the
IC-Camera offset
function.
Press the ESC key to return to the SITEST main menu.
Pos.calibration tool
Adopt current pos.
Teach position
PCB-camera
Component camera
IC-camera
Flip-chip-camera
Vision system
IC-camera
Move to by pcb-cam.
Move to by IC-head
IC-ca.pos & offset
Calibrate IC-camera
Illumination test
Illumination for GF
Meas.focus camera
Illumination values
Calibration factors
Camera number
IC-ca.pos & offset
Camera position
IC-Camera offset
Measure
User’s Manual Test Program SITEST 3 Calibration Functions
Software Version 10.xx Edition 03/98 3.9 Calibration of the Flip-Chip Camera (SIPLACE 80F)
3 - 17
3.9 Calibration of the Flip-Chip Camera (SIPLACE 80F)
Carry out the preparatory steps proceeding as described in section 3.1 and section 3.1.1.
From the "Vision system" menu select the Flip-chip-camera option and press the RETURN key.
The "Flip-chip-camera" menu is displayed on the screen.
Overview of the Functions:
-
Camera position Menu for entering or determining the Flip-Chip camera position
-
Calibrate camera to calibrate the Flip-Chip camera
-
Meas.focus camera Menu for measuring the focus position of the Flip-Chip camera
-
Calibration factors to display the Flip-Chip camera values determined
-
Camera number to open the input field for the camera number
From the "Flip-chip-camera" menu select the Meas.focus camera option.
The "Meas.focus camera" menu is displayed on the screen.
Overview of the Functions:
-
Pick up cal. tool to pick up the calibration piece with the IC-head
-
Return cal. tool to deposit the calibration piece in the calibration piece pocket
-
Measure focus to measure the focus position
-
Measure z-Delta to determine the z-delta
(from conveyor top edge to focus position of Flip-Chip camera)
-
Focus pos. to display the focus position measured
-
z step size (digit) to enter or modify the z step size for the focus adjustment
Pos.calibration tool
Adopt current pos.
Teach position
PCB-camera
Component camera
IC-camera
Flip-chip-camera
Vision system
Flip-chip camera
Camera position
Calibrate camera
Meas.focus camera
Calibration factors
Camera number
Pos.calibration tool
Adopt current pos.
Teach position
PCB-camera
Component camera
IC-camera
Flip-chip-camera
Vision system
Flip-chip camera
Camera position
Calibrate camera
Meas.focus camera
Calibration factors
Camera number
Meas.focus camera
Pick up cal. tool
Return cal. tool
Measure focus
Measure z-Delta
Focus pos. (digit)
z step size (digit)