User’s Manual Test Program S ITEST Software Version 10.xx Edition 03/98 4 - II

100%1 / 88
User’s Manual Test Program SITEST
Software Version 10.xx Edition 03/98
4 - I
Contents
Page
Mapping
4.1 Preparatory Steps for the Mapping Operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 - 1
4.1.1 PCB Mapping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 - 2
4.1.2 RV-Mapping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 - 6
4.1.3 IC-Mapping. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 - 8
User’s Manual Test Program SITEST
Software Version 10.xx Edition 03/98
4 - II
User’s Manual Test Program SITEST 4 Mapping
Software Version 10.xx Edition 03/98 4.1 Preparatory Steps for the Mapping Operation
4 - 1
4 Mapping
WARNING
!
!
The gantries will be moving during the performance of the function described in this section. Prior to the exe-
cution of this function make sure that neither any part of your body nor any objects are in the traversing range
of the gantries - DANGER OF INJURY.
Functions of the different types of mapping
PCB Mapping:
In PCB mapping, the gantry position is measured in relation to a high-precision glass plate. The data thus
determined are stored and used by the station software for the corrrection of the X and Y-coordinates.
RV Mapping:
Owing to the gantry offset, the PCB - RV camera offset (X- and Y-distance between the camera and the
revolver head) depends on the gantry position. RV mapping is designed to determine any change of the
PCB-RV- camera offset at the respective measuring points of the glass plate. The data thus determined are
stored for use by the station software.
IC Mapping:
Owing to the gantry offset, the RV camera - IC tube offset (X- and Y-distance between the camera and the
tube) depends on the gantry position. IC mapping is designed to determine any change of the RV camera - IC
tube offset at the respective measuring points of the glass plate. The data thus determined are stored for use
by the station software.
4.1 Preparatory Steps for the Mapping Operation
Using the "RV-Head ref. run", "IC-head refer. run" and "Gantry refer. run" menu functions have the gantries
approach their reference positions.
Select the Select gantry option (applies to SIPLACE 80S only) and press the RETURN key.
The "Select gantry" menu opens.
Select the gantry 1 active menu option for gantry 1 and press the RETURN key.
Press the ESC key to return to the SITEST main menu.
Select the Functions menu option and press the RETURN key.
The "Functions" menu opens.
Select the Width adjustment menu option and press the RETURN key.
The "Width adjustment" menu opens.
Adjust the width of the PCB conveyor to the width of the mapping plate using the functions of the "Width
adjustment" menu.
Press the ESC key to return to the "Functions" menu.
Select the Conveyor menu option and press the RETURN key.
The "Conveyor" menu opens.
Manually slide the PCB stopper to the center of the conveyor width.
Select the PCB Stopper function to extend the stopper and press the RETURN key.
The stopper is extended.