2 Functions for the A djustment of the Machine User’s Manual Test Program S ITEST 2.5 Continuous Run Software Version 10.xx Edition 03/98 2 - 16 ● To perfor m a co ntinuous run of the RV-head, selec t the Enter Para mete…

100%1 / 88
User’s Manual Test Program SITEST 2 Functions for the Adjustment of the Machine
Software Version 10.xx Edition 03/98 2.5 Continuous Run
2 - 15
-
Print vacuum results to print the measured vacuum values
-
Alternate IC-vacuum to switch the vacuum for the IC-head on/off
-
Alternate IC air blow to switch the "blow air" supply for the IC-head on/off
-
Measure IC vacuum to measure the vacuum values of the IC-head
From the "Vacuum" menu select the desired function and press the RETURN key
.
The selected function is executed.
Press the ESC key to exit from the "Vacuum" menu.
2.5 Continuous Run
This function is designed to perform a complete head test.
NOTE
Prior to starting the continuous run, the respective placement head must have been submitted to a reference
run and the gantry must be so positioned that upon lowering the z-axis the sleeve will either make contact with
the conveyor top edge or a PCB located in the center conveyor.
From the main menu select the Continuous run option and press the RETURN key.
The "Continuous run" menu is displayed on the screen.
Overview of the Functions:
-
Ct.run RV-head to perform a continuous run of the RV-head
-
Cont.run IC-head to perform a continuous run of the IC-head
-
Ct.r. FORCE RV-head to open the start menu for the "RV-head" endurance run
-
Ct.r. FORCE IC-head to open the start menu for the "IC-head" endurance run
Continuous run
Ct.run RV-head
Cont.run IC-head
Ct.r. FORCE RV-head
Ct.r. FORCE IC-head
2 Functions for the Adjustment of the Machine User’s Manual Test Program SITEST
2.5 Continuous Run Software Version 10.xx Edition 03/98
2 - 16
To perform a continuous run of the RV-head, select the
Enter Parameter
menu option from the "Conti-
nuous run" menu and press the RETURN key.
The "Ct.run RV-head" menu is displayed on the screen.
Overview of the Functions:
-
Start cont. run head to start the continuous run
-
Display result the results of the head continuous run are read back by the machine controller and
displayed on the screen.
-
Print result to print the results of the head continuous run on a connected printer
-
Reset counter to reset the sequence and error counter
-
Enter head data to open the "Head data" input menu (head number, data, tester's name)
-
Enter parameter to open the menu for the entry of sequence parameters for the head continuous run
(z-sensor path in DIGITS, number of passes up to the reference run, number of
passes up to the vacuum check, with/without centering)
If you wish to enter the head data, select the
Enter head data
menu option and press the RETURN key.
The input menu is opened.
Enter the desired data and press the RETURN key to store the data.
Press the ESC key to exit from the input menu.
If you wish to change the parameters for the performance of the head continuous run, select the
Enter
parameter
menu option and press the RETURN key.
The input menu is opened.
Carry out the desired changes and press the RETURN key to store the changes.
Example: If you enter the figure "100" on the "Reference run" line, this means that the reference
point will be checked after 100 cycles of the revolver head (1 cycle = 12 incremental steps).
If you enter the figure "100" on the "Vacuumtest" line, this means that
a vacuum check will be performed after 100 cycles of the revolver head.
Press the ESC key to exit from the input menu.
Select the
Start cont. run head
function to start the head continuous run and press the RETURN key.
The continuous run continues to be executed until it is terminated by pressing the ESC key.
If you wish to execute another function of the "Ct.run RV-head" menu, select the desired function from the
menu and press the RETURN key
.
The selected function is executed.
Continuous run
Ct.run RV-head
Cont.run IC-head
Ct.r. FORCE RV-head
Ct.r. FORCE IC-head
Start cont. run head
Display result
Print result
Reset counter
Enter head data
Enter parameter
Ct.run revolver head
User’s Manual Test Program SITEST 2 Functions for the Adjustment of the Machine
Software Version 10.xx Edition 03/98 2.5 Continuous Run
2 - 17
Press the ESC key to exit from the "Ct.run RV-head" menu.
If you wish to have the RV-head perform an endurance run. select the
Ct.r. FORCE RV-head
menu
option from the "Continuous run" menu and press the RETURN key
.
The "Ct.r. FORCE RV-head" menu is displayed on the screen.
Overview of the Functions:
-
Start cont.run FORCE to start the continuous run
-
Change parameter to open the menu for changing the run parameters for the endurance run
If you wish to change the force setting at which the continuous run is to be carried out, select the
Change
parameter
menu option and press the RETURN key.
The input menu is opened.
Change the force setting to the desired value and press the RETURN key to accept the change.
Press the ESC key to exit from the input menu.
To start the endurance run select the
Start cont.run FORCE
function and press the RETURN key.
The continuous run continues to be carried out until you terminate it by pressing the ESC key.
Press the ESC key to return to the "Continuous run" menu.
To perform a continous run of the IC-head, select the
Cont.run IC-head
menu option from the "Continuous
run" menu and press the RETURN key.
The "Cont.run IC-head" menu is displayed on the screen.
Overview of the Functions:
-
Start cont. run head to start the continuous run
-
Change parameter to open the menu for changing the run parameters for the head continuous run
-
Display result the results of the continuous head run are read back by the machine controller
and displayed on the screen.
If you wish to change the parameters for the execution of the continuous head run, select the
Change
parameter
menu and press the RETURN key.
The input menu is opened.
Continuous run
Ct.run revolver head
Cont.run IC-head
Ct.r. FORCE rev.head
Ct.run FORCE IC-head
Start cont.run FORCE
Change parameter
Ct.r. FORCE RV-head
Continuous run
Ct.run revolver head
Cont.run IC-head
Ct.r. FORCE rev.head
Ct.run FORCE IC-head
Start cont. run head
Change parameter
Display result
Cont.run IC-head