00191174-01.pdf - 第24页
1 General Functions User’s Manual Test P rogram SITEST 1.6 "Miscellaneous" Menu Software Version 10.xx Edition 03/98 1 - 12 ● To set t he desired transpor t mode , select the Transport mode menu option a nd pre…

User’s Manual Test Program SITEST 1 General Functions
Software Version 10.xx Edition 03/98 1.6 "Miscellaneous" Menu
1 - 11
Overview of the Functions:
-
Type of conveyor Menu for selecting the current conveyor type (e.g. left conveyor)
-
Transport mode Menu for selecting the range of PCB lengths for PCBs that are to be processed on
the machine
-
Ceramic s. centering Menu for selecting the type of ceramic substrate centering
-
4x5 IC-Noz. Changer To set the default values for the 4x5 IC nozzle changer
●
To determine the currently installed conveyor, select the
Type of conveyor
menu option from the
"Machine-Config." menu and actuate the RETURN key.
The "Type of conveyor" menu is displayed on the screen.
Overview of the Functions:
-
Right conveyor The fixed side of the conveyor, including calibration piece pocket and integrated
measuring hole for the MA zero point, is located on the right (viewing in the
direction of PCB travel).
Left conveyor The fixed side of the conveyor, including calibration piece pocket and integrated
measuring hole for the MA zero point, is located on the left (viewing in the direc-
tion of PCB travel).
-
Standard conveyor The fixed side of the conveyor including calibration piece pocket is located on the
right (viewing in the direction of PCB travel). The measuring hole for the MA zero
point is integrated in the setting gauge. (The setting gauge is placed on the ele-
vating table).
●
Select the type of conveyor installed in the machine and actuate the RETURN key. The selected conveyor
type is displayed on the screen.
NOTES
By selecting the conveyor type you also define for subsequent calibration operations to be performed
where the calibration piece pocket, the MA zero point or the PCB reference corner is located.
The selection of the conveyor type is to be carried out once upon the intital start-up, prior to the perfor-
mance of calibration. transport and mapping functions, or whenever the conveyor and/or the calibration
piece pocket are modified or newly installed.
If a new conveyor type was selected and stored, the positions of the MA zero point, the calibration piece
and the PCB reference corner must be recalibrated because they were assigned default values.
●
Actuate the ESC key to return to the "Machine-Config." menu.
Miscellaneous
Options
Display files
Version description
Clear screen
Dispaly file
Configuration
Operation parameter
Machine-Config.
Type of conveyor
Transport mode
Ceramic s. centering
4x5 IC-Noz. Changer
Machine-Config.
Right conveyor
Left conveyor
Standard conveyor
Type of conveyor

1 General Functions User’s Manual Test Program SITEST
1.6 "Miscellaneous" Menu Software Version 10.xx Edition 03/98
1 - 12
●
To set the desired transport mode, select the
Transport mode
menu option and press the RETURN key.
The "Transport mode" menu is displayed on the screen.
Overview of the Functions:
-
Standard PCB (460mm) Setting for the assembly of PCBs with a length of 50 - 460 mm.
(If the "Standard PCB" option is activated, PCBs may be located in the input,
center and output conveyors).
-
Long PCB (508mm) Setting for the assembly of PCBs with a length of 50 - 508 mm.
(If the "Long PCB" option is activated, the individual PCBs will be transported
into the center conveyor section with some time lag).
-
Super long PCB Setting for the assembly of extremely long PCBs.
(If the "Super long PCB" option is activated, no PCB will be moved into the input
conveyor as long as there is a PCB present in any of the 3 conveyor sections).
This option is currently not supported by SITEST- and station-software.
●
Select the desired option and press the RETURN key. The selected option is displayed on the screen.
●
Press the ESC key to return to the "Machine-Config." menu.
●
Select the
Ceramic s. centering
menu item if you wish to set the ceramic substrate centering type availa-
ble in the machine configuration and press the RETURN key.
The "Ceramic s. centering" menu is displayed on the screen.
Miscellaneous
Options
Display files
Version description
Clear screen
Dispaly file
Configuration
Operation parameter
Machine-Config.
Type of conveyor
Transport mode
Ceramic s. centering
4x5 IC-Noz. Changer
Machine-Config.
Standard PCB (460mm)
Long PCB (508mm)
Super long PCB
Transport mode
Miscellaneous
Options
Display files
Version description
Clear screen
Dispaly file
Configuration
Operation parameter
Machine-Config.
Type of conveyor
Transport mode
Ceramic s. centering
4x5 IC-Noz. Changer
Machine-Config.
None
Mechanical
Optical (PCB-camera)
Both
Ceramic s. centering

User’s Manual Test Program SITEST 1 General Functions
Software Version 10.xx Edition 03/98 1.6 "Miscellaneous" Menu
1 - 13
Overview of the Functions:
-
None Select if no ceramic substrate centering is available
-
Mechanical Select if a mechanical ceramic substrat centering feature is installed
-
Optical (PCB-camera) Select if an optical ceramic substrat centering feature is installed
-
Both Select if mech. and opt. ceramic substrat centering features are installed
●
Select the desired option and press the RETURN key. The selected option is displayed on the screen.
●
Press the ESC key to return to the "Machine-Config." menu.
Configuration of the "4 x 5" IC Nozzle Changer
●
Select the
4x5 IC-Noz. Changer
menu option and press the RETURN key.
The "4x5 IC-Noz. Changer" menu is displayed on the screen
●
Select the
Change
menu function if you wish the "4 x 5" IC nozzle changer to be added to the machine
configuration, and press the RETURN key.
●
Press the ESC key three times to return to the SITEST main menu.
NOTE
The default values of the nozzle changer will be accepted by the system when the
Store MA-file
menu function is selected (see section 1.3).
Following the acceptance of the default values, the nozzle changer must be recalibrated.
Options
Display files
Versions description
Clear screen
Display file
Configuration
Operation parameter
Machine-Config.
Type of conveyor
Transport mode
Ceramic s. centering
4x5 IC-Noz. Changer
Miscellaneous
Machine-Config.
Change
Abort
4x5 IC-Noz. Changer