3 Calibration Functions User’s Manual Test P rogram SITEST 3.5 Calibration of t he Machine Zero Point Software Version 10.xx Edition 03/98 3 - 10 ● From th e "Gantr y posi tions " menu select t he Move to posit…

100%1 / 88
User’s Manual Test Program SITEST 3 Calibration Functions
Software Version 10.xx Edition 03/98 3.5 Calibration of the Machine Zero Point
3 - 9
Enter the number of the segment to be measured and confirm your entry by pressing the
RETURN key.
Exit from the input menu by pressing the ESC key.
Select the
Measure segm. offs.I
function and press the RETURN key. The selected segment is
measured. The further procedure corresponds to that described for the "All seg. offsets I" function.
3.5 Calibration of the Machine Zero Point
NOTE
Verify that the calibration data for the component camera, PCB camera, and PCB/
component camera offset have already been determined.
On SIPLACE 80S machines, the calibration of the machine zero point must be performed for both gantries
directly one after the other!
Place setting gauge onto the locating pins in the elevating table.
WARNING
!
!
Make absolutely sure that the setting gauge is so installed that its height is flush with the upper edge of
the conveyor. An acute DANGER OF CRASH exists when the gantry axes are moved with the
lifting
table in raised position
with the setting gauge mounted
.
From the main menu select the
Gantry positions
option and press the RETURN key.
The "Gantry positions" menu is displayed on the screen.
Overview of the Functions:
-
Move to position Menu to approach the machine positions
-
Calibrate Calibration menu (MA zero point, pick-up positions, calibration piece position,
PCB reference corner position)
-
Display position Menu to display the positions determined under "Calibrate"
-
Double gantry funct. The function is not available in this software version.
Move to position
Calibrate
Display position
Double gantry funct.
Gantry positions
3 Calibration Functions User’s Manual Test Program SITEST
3.5 Calibration of the Machine Zero Point Software Version 10.xx Edition 03/98
3 - 10
From the "Gantry positions" menu select the
Move to position
option and press the RETURN key. The
"Move to position" menu is displayed on the screen.
Overview of the Functions:
-
Park position to approach the park position
-
Machine zero-point to approach the machine zero point (measuring hole in the setting gauge or in
the segment of the calibration piece pocket) with the PCB camera
-
Pos.calibration tool to approach the position of the calibration piece in the calibration piece pocket with
the PCB camera
-
Track 1 to approach track 1 with the PCB camera
-
Track 120 to approach track 120 with the PCB camera
-
Fixed PCB corner
I
to approach the PCB reference corner position
I
with the PCB camera
(on SIPLACE 80S machines only possible with gantry 1)
Select the
Machine zero-point
function, press the RETURN key and the START button.
The PCB camera moves over the measuring hole for the MA zero point.
Switch the monitor to the PCB camera using key combination ALT+8.
Check whether the measuring hole for the machine zero point is located in the search field of the camera.
If the maesuring hole is not within the PCB camera’s field of view, the zero point correction of the gantry
axes must be changed until the measuring hole is located in the search window.
Switch the monitor back to the normal program mode using key combination ALT+9.
Press the ESC key to return to the "Gantry positions" menu.
Select the
Calibrate
menu item and press the RETURN key. The "Calibrate" menu is displayed on the
screen.
Overview of the Functions:
-
Machine zero-point to calibrate the machine zero point
-
Track 1 to calibrate the position of track 1
-
Track 120 to calibrate the position of track 120
-
Tr. 1 no positioning to determine the position of the measuring hole in the setting gauge and to save the
values determined as the pick-up position of track 1
(The PCB camera must first be taught over the measuring hole of the setting gauge).
Move to position
Calibrate
Display position
Double gantry funct.
Gantry positions
Move to position
Park position
Machine zero-point
Pos.calibration tool
Track 1
Track 120
Fixed PCB corner I
Move to position
Calibrate
Display position
Double gantry funct.
Gantry positions
Calibrate
Machine zero-point
Track 1
Track 120
Tr.1 no positioning
Tr.120 no positioning
Pos.calibration tool
Fixed PCB corner I
User’s Manual Test Program SITEST 3 Calibration Functions
Software Version 10.xx Edition 03/98 3.6 Measuring the Pick-Up Positions of Tracks 1 and 120
3 - 11
-
Tr. 120 no positioning to determine the position of the measuring hold in the setting gauge and to save the
values determined as the pick-up position of track 120
(The PCB camera must first be taught over measuring hole of the setting gauge).
-
Pos.calibration tool to calibrate the calibration piece position (on SIPLACE 80S only possible with
gantry 1)
-
Fixed PCB corner
I
to calibrate the PCB reference corner position
I
(on SIPLACE 80S only possible with gantry 1)
Select the
Machine zero-point
function, press the RETURN key and the START button.
The calibration of the machine zero point is performed.
Press the ESC key twice to return to the SITEST main menu.
Save the data of the calibrated machine zero point using the
File Manager
->
Store MA-file
menu function
(see section 1.3).
3.6 Measuring the Pick-Up Positions of Tracks
1 and 120
NOTE
Verify that the calibration data for the component camera, PCB camera, PCB/component camera offset and
the machine zero point have already been determined.
Place the setting gauge onto track 1 or 120 of the component table to be measured.
NOTE
Check the component table beforehand for any unevenness or contamination.
From the main menu select the
Gantry positions
option and press the RETURN key.
The "Gantry positions" menu is displayed on the screen.
From the "Gantry positions" menu select the
Calibrate
option and press the RETURN key. The "Calibrate"
menu is displayed on the screen.
Depending on the position of the setting gauge on the component table, select function
Track 1
or
Track
120
, press the RETURN key and the START button. The calibration of the selected track is performed.
Proceed in the same way for the other track.
NOTE
The feeder location "1" (or "2" where a WPC is installed) of the SIPLACE 80F system cannot be measured
automatically owing to the fact that the tracks of this feeder location cannot be approached by the PCB
camera on account of the traversing range of the gantry being too small.
Press the ESC key twice to return to the SITEST main menu.