5 Configuration User Manual - Productivity Lift Soko 00166631-01 / 12031477 5.17 Reference width 2 Software version V 43.140 Edition April 2006 58 5.17 Reference wid th 2 This setting defines the refer ence width o f the…

User Manual - Productivity Lift Soko 00166631-01 / 12031477 5 Configuration
Software version V 43.140 Edition April 2006 5.16 Reference width 1
57
5.16 Reference width 1
This setting defines the reference width of the Shuttle Conveyor. This setting allows the matching
of displayed width and actual width of the Shuttle Conveyor. By changing the setting the width is
increased or decreased. A typical value is between 0480 - 0490.
This menu item is only available, if the function „Width adjustment 1” is activated (chapter 5.12).
The standard configuration is equipped with an automatic width setting of the Shuttle Conveyor.
The unit of value is [0.1mm].
Fig. 5 - 16 Reference width 1
ALT
Enter
Start
Stop
Reference width 1
0480

5 Configuration User Manual - Productivity Lift Soko 00166631-01 / 12031477
5.17 Reference width 2 Software version V 43.140 Edition April 2006
58
5.17 Reference width 2
This setting defines the reference width of the Underfloor Conveyor. This setting allows the match-
ing of displayed width and actual width of the Underfloor Conveyor. By changing the setting the
width is increased or decreased. A typical value is between 0480 - 0490.
This menu item is only available, if the function „Width adjustment 2” is activated (chapter 5.13).
The standard configuration is equipped with an automatic width setting of the Underfloor Con-
veyor.
NOTE
If the lift is implemented as an end module, this menu does not appear.
The unit of value is [0.1mm].
Fig. 5 - 17 Reference width 2
5.18 Max. width board
Here the maximum transport width permissible for the system is set. The unit of value is [0.1mm].
The setting range is between 500 and 4600, which corresponds to a width of 50mm to 460mm.
Fig. 5 - 18 Max. width board
ALT
Enter
Start
Stop
Reference width 2
0490
ALT
Enter
Start
Stop
Max. width board
4600

User Manual - Productivity Lift Soko 00166631-01 / 12031477 5 Configuration
Software version V 43.140 Edition April 2006 5.19 Start speed down
59
5.19 Start speed down
The speed at which the lower lift starts up when travelling downwards and which is reverted to by
braking just before reaching the final position.
The setting is a percentage of the motor rating. The value should be between 23% and 27%. The
default setting are 25%.
Fig. 5 - 19 Start speed down
5.20 Start speed up
The speed at which the lower lift starts up when travelling upwards and which is reverted to by
braking just before reaching the final position.
The setting is a percentage of the motor rating. The value should be between 20% and 25%. The
default setting are 20%.
Fig. 5 - 20 Start speed up
ALT
Enter
Start
Stop
Start speed down
025
ALT
Enter
Start
Stop
Start speed up
020