Carefully rub the following contact surfaces with a dressing
stone and wipe clean with a cloth and ethanol.
1. Magnet support
2. Contact surfaces of the 4 guide slides
3. Contact edges of the 4 guide slides
Enlist the help of a second strong person. Lift the gantry up to
the guide slides and secure the gantry at the top with two
screws (M4 x 14).
Then loosely screw in the remaining screws. Observe the
correct screw lengths.
SIPLACE HF
Replacing the Gantry [03006781-xx]
Service
Gantries
3
Copyright © 2003 Siemens Dematic SDEA 1 00194307-01 Issue 12/2003 3-9
2
1
2
Do not tighten the fastening screws yet!
Lift the far end of the gantry (1) so that the gantry rests on the
contact edges of the top guide slide (2).
Tighten the top fastening screws.
Then tighten all 16 fastening screws with the aid of the special
torque wrench (9.5 N).
3
Service
Gantries
SIPLACE HF
Replacing the Gantry [03006781-xx]
3-10
00194307-01 Issue 12/2003 Copyright © 2003 Siemens Dematic SDEA 1
1
With the aid of a 1/100 plastic thickness gauge, check the gap
between the portal contact edge and the guide slide (1). The
gantry must lie flush with the guide slide, leaving no room in-
between for the thickness gauge.
If this is not the case, dismantle the gantry and clean the