00194307-01_SAHF_Intern_1203_ENG.pdf - 第43页
SIPLACE HF Replacing the X -Axis Read Head [030 06472] Serv ice Gan tri es 3 Copy ri ght © 2 00 3 S iem ens D emat ic SDEA 1 0019 4307- 01 Iss ue 12/2 003 3-33 5 1 3 2 1. Visi on board 2. Head interf ace ( under the V is…

3
Service
Gantries
SIPLACE HF
Replacing the X-Axis Read Head [03006472]
3-32
00194307-01 Issue 12/2003 Copyright © 2003 Siemens Dematic SDEA 1
3.1.5 Replacing the X-Axis Read Head [03006472]
1
1. Position of the X-axis read head

SIPLACE HF
Replacing the X-Axis Read Head [03006472]
Service
Gantries
3
Copyright © 2003 Siemens Dematic SDEA 1 00194307-01 Issue 12/2003 3-33
5
1
3
2
1. Vision board
2. Head interface (under the Vision board)
3. Read head position
Unplug the read head plug-and-socket connection from the
head interface (2).
Plug-and-Socket Connections
Assembly Gantry Board Terminal
X-axis read head Gantry 1 (DLM head) Head interface 03000901 X15ac
X-axis read head Gantry 2 (Twin head) Head interface 03000901 X15bc

3
Service
Gantries
SIPLACE HF
Replacing the X-Axis Read Head [03006472]
3-34
00194307-01 Issue 12/2003 Copyright © 2003 Siemens Dematic SDEA 1
Disassembly
4
3
1
2
1. Head mount - front view
2. Read head
3. Fastening screws
4. Grub screws for fastening
CAUTION
Do not loosen or unscrew the grub screw (4).
Unthread the connection cable as far as the read head (2).
Undo the three screws (3) fastening the X-axis read head (2)
and carefully lift off the read head.