S M T S o f t w a r e E n g i n e e r i n g G r o u p I M O p e r a t i o n s Y A M A H A M O T O R C O . , L T D . MDOC-SOFT501 16 16/48 2.3.7. Detailed explanation of the “Board name check” In the board name check, it …

SMT Software Engineering Group
IM Operations YAMAHA MOTOR CO., LTD.
MDOC-SOFT50116 15/48
2.3.6. Detailed explanation of the “Recovery”
If any proper badmark recognition result cannot be obtained from the upstream machine,
the machine stops by error. When the recovery is made valid, the operation continues while
referring to the badmark on the board if the machine does not stop due to error occurrence.
To use this function, it is necessary that the badmark on the board can be referred to. When
the operation is performed that the badmark on the board does not meet the badmark
recognition result file or when no badmark exists on the board, this function needs to be set
invalid.
(Caution) For operations stated in section “2.1.2 Special application examples”, this
function is set invalid.
The following shows typical cases that the badmark recognition results are not obtained.
Board carryin
No badmark recognition result file is found.
Operation restart
The operation restarts in the status different from that before error stop.
1. Error occurs.
2. Operation restarts with the board placed at a position different from the error stop
position.
When the board stock state does not change, the same status as before operation is
kept even when pressing the RESET. Therefore, when restarting the operation, the
operation is performed according to the badmark recognition result before the error
stop.
Recovery Board carryin Operation restart
Valid Badmark is recognized again. Badmark is recognized again.
Invalid Error stops. Error stops.
?

SMT Software Engineering Group
IM Operations YAMAHA MOTOR CO., LTD.
MDOC-SOFT50116 16/48
2.3.7. Detailed explanation of the “Board name check”
In the board name check, it is checked that the board name of the badmark recognition
result file meets the board name currently used for the production.
This function is used to ensure the consistency between the board and badmark recognition
result file in the operation without using the board ID. Note that there are cases that the
operation is performed with different board name by machine when producing one product
type. When such operation is performed, the board name is checked off or the board name
is unified.
AssyNo
Y001
Program
Y001
Program
Y001
Program
Y001
Program
Y001
Program
Y002
Program
Y003

SMT Software Engineering Group
IM Operations YAMAHA MOTOR CO., LTD.
MDOC-SOFT50116 17/48
2.4. Others
2.4.1. Machine common
2.4.1.1. Operation of mixed line
The badmark transfer can be operated even in a line with the Xg and YGseries mixed.
At this time, it is necessary to install a custom specification (Tok660: TRANSPORT BAD
RESULT) into the Xg and YGseries.
2.4.1.2. Badmark recognition result
The badmark recognition result can be checked through the monitor screen. Additionally,
when the badmark is transferred, the badmark recognition result is displayed after the data
has been transferred.
The badmark recognition result can be checked by choosing [Monitor][Badmark].
For details, refer to the badmark from “Monitor display during production” stated in
“YSseries Operator’s Manual”.
Table Select
Badmark Type
Block No
Lane
Result