TM5761.Badmark Transfer.pdf - 第38页

S M T S o f t w a r e E n g i n e e r i n g G r o u p I M O p e r a t i o n s Y A M A H A M O T O R C O . , L T D . MDOC-SOFT501 16 38/48 5.1. Corrective acti ons to be t ak en in case on an error As the automatic operat…

100%1 / 48
SMT Software Engineering Group
IM Operations YAMAHA MOTOR CO., LTD.
MDOC-SOFT50116 37/48
Error No. Contents
It is failed to write the badmark recognition result file.
[Cause]
It is failed to write the badmark recognition result file.
[Action]
Check that the folder set in “Download” can be written.
Check the setting contents of [Software setting][TakeOver Information].
 When the output is not needed, control the output.
Check off the [Download] check box on the [Software setting][Take Over
Information] screen.
Ea12856
File name
File name
Combinations that cannot be operated are specified.
[Cause]
Even when “Upload” is not used, the recovery function is also set disabled.
Ea12859
[Action]
When “Upload” is not used, set the recovery function enabled.
Combinations that cannot be operated are specified.
[Cause]
Machine with [Machine][Mechanical][Position][Badmark][TakeOver][Enable
(Leadoff)] set has the following setting.
・ [Upload] is checked on.
・ Recovery function is set disabled.
Ea12872
[Action]
For the machine with
[Machine][Mechanical][Position][Badmark][TakeOver][Enable (Leadoff)] set,
check off [Upload] and set the recovery function enabled.
No move destination folder is specified.
[Cause]
No move destination folder is specified.
Ea12977
[Action]
Set a move destination folder.
The same folder as the move source is set for the move destination folder.
[Cause]
The same folder as the move source is set for the move destination folder.
Ea12978
[Action]
Change the move destination folder to a folder different from the move source
folder.
The badmark recognition result file cannot de identified.
[Cause]
The badmark recognition result file cannot be identified.
・ No badmark recognition result file is found.
・ The badmark recognition result is different from that of the upstream
machine.
Ea12979
[Action]
Correct the unmatched data and load the board from the upstream machine
again.
A block No is set that does not exist in the original block Nos of the print inspection object.
[Cause]
A block No is set that does not exist in the original block Nos of the print
inspection object.
[Action]
Check the offset information and set a valid block No.
Ea24609
Print inspection object nn
Original block No. nn
A local badmark No is set that does not exist in the bad of the print inspection object.
[Cause] A local badmark No is set that does not exist in the bad of the print inspection
object.
[Action] Check the badmark information and set a valid local badmark No.
Ea24610
Print inspection object nn
Bad nn
SMT Software Engineering Group
IM Operations YAMAHA MOTOR CO., LTD.
MDOC-SOFT50116 38/48
5.1. Corrective actions to be taken in case on an error
As the automatic operation is restarted after the error recovery, the operation restarts with
the badmark transferred data retained when the board stock state is the same as that before
the error stop.
5.1.1. Taking actions in case of an error
1. If an error occurs, check the board position.
You can make the check by choosing [Unit][Conveyor].
2. Taking corrective actions
Follow the contents of the error message to take corrective actions.
SMT Software Engineering Group
IM Operations YAMAHA MOTOR CO., LTD.
MDOC-SOFT50116 39/48
3. Restoring the state
Return the board to the state that is the same as error occurrence, when the board is
moved.
The operation cannot be restarted if the board stock state is different. To restart the
operation in the different board stock state, load the board from the upstream machine
again.
4. Restarting the automatic operation
Restart the automatic operation.
Different
board stock state