YSP10_Mainte_E.pdf - 第44页
2. The daily inspection and cleaning 2-6 Chapter 2 Daily maintenance items 2.5 Mask vacuum unit, boar d flap and edge clamp plate Check the condition of mask v acuum unit (mask plate), board flap (hereinafter referred to…

2. The daily inspection and cleaning
2-5
Chapter 2 Daily maintenance items
2.4 Cleaning unit
Check the condition of cleaning unit before starting operation. Check the following items visually.
►
Daily inspection items
• The cleaner head unit is not contaminated.
• The cleaning gauze is attached correctly. (See the image below)
• The cleaning gauze can be winded up without slack.
• The cleaning alcohol tank (at the left side of the machine front side) is filled enough.
n
NOTE
See attached "User's manual" for details of the cleaning gauze setting procedure.
Cleaning unit
Cleaner head and Cleaning gauze
The cleaning gauze is removed.
The cleaning gauze is attached.
Cleaner head
Cleaner head
Check the contamination and clean it.
Check if the cleaning gauze is attached correctly.
Side to be attached
Side to be attached
Side to be winded up
Guide
Without slack
53208-KMJ-00
►
Treatments
• When the cleaner head is not clean, wipe with lint-free cloth (with a few drops of alcohol when
needed).
• When the cleaner gauze is not attached correctly, remove it and reattach referring to the image
above.
• When the cleaner gauze cannot be winded correctly with slack, press the [Feed gauze] button on
[Unit] - [Cleaner] screen few times until the slack is eliminated.

2. The daily inspection and cleaning
2-6
Chapter 2 Daily maintenance items
2.5 Mask vacuum unit, board flap and edge clamp plate
Check the condition of mask vacuum unit (mask plate), board flap (hereinafter referred to as flap) and edge
clamp plate (hereinafter referred to as edge plate) before starting operation. Check the following items.
►
Daily inspection items
• No adherence of solder etc. on the mask plate and extended conveyor plate.
• No adherence of solder etc. on the flap.
• No adherence of solder etc. or no wears on the edge plate*.
*When the edge plate worn out, a board imprint remains on it.
Mask vacuum unit, board flap and edge clamp plate
Mask plate
Edge plate
Flap
Extended conveyor plate
Extended conveyor plate
Lint-free cloth
(with a few drops of ethanol)
Underside of flap
Solder adherence
Lint-free cloth
(with a few drops of ethanol)
53209-KMJ-00
►
Treatments
• When the adherence of solder etc. is found on the mask plate, extended conveyor plate, flap or
edge plate, wipe with lint-free cloth with a few drops of absolute ethanol.
• The adherence of solder may be found on the underside of flap, so wipe it with care.
• When the edge plate is worn out, it requires to be replaced. Contact to your sales representative.
n
NOTE
When the back of the mask is not cleaned well, dirt may remain during the inspection. Clean the mask completely after
use, and review the mask cleaning setting as necessary.

2. The daily inspection and cleaning
2-7
Chapter 2 Daily maintenance items
2.6 Solder drop prevention plate (option)
Check the solder drop prevention plate condition before starting daily operation. Check the following items.
►
Daily inspection items
No adherence of solder etc. on the solder drop prevention plate.
2.6.1 Fixed type
When some solder etc. adheres, wipe off using lint-free cloth with a few drops of ethanol.
n
NOTE
When the cleaning has difficulty, detach the squeegee before cleaning
Solder drop prevention plate
Fixed type
Solder drop prevention plate
Lint-free cloth (with a few drops of ethanol)
Solder adherence
53210-KMJ-00