YSP10_Mainte_E.pdf - 第57页

2. Monthly maintenance 3-10 Chapter 3 Periodic maintenance items 4 Mov e camera unit to mac hine rear side by t he work f rom rear side. Move camera unit to ma chin e rear side grabbing its handle, by the w ork from rear…

100%1 / 130
2. Monthly maintenance
3-9
Chapter 3 Periodic maintenance items
Optional type
1
e
Detach machine safety cover.
1. Press the emergency safety button to ensure
the safety of work.
2. Remove 4 screws of center rear cover of
machine using Phillips screwdriver, then
detach center rear cover.
c
CAUTION
Be careful not to be injured by dropping down the cover.
2
Move camera unit to machine front side
grabbing its handle, by the work from
rear side.
3
Detach screws of CX-axis cover front
side by the work from front side.
1. Open machine safety cover.
2. Move the universal mask holder into
machine inside until the screws of CX-axis
cover front side can be seen, while pressing
the button illustrated at right.
3. Remove 4 screws of CX-axis cover front side
(2 screws each on left and right) using
Phillips screwdriver.
TIP
When the machine is installed "Standard (fixed) mask
holder (L736 x W736 or more)" and "Automatic mask
exchange unit", the detaching procedure of screws of
CX-axis cover front side is different.
See "Standard (fixed) mask holder (L736 x W736 or
more)" for details.
Detaching center rear cover
Optional type
Step 1
4 screws
Center rear cover
53388-KMJ-00
Move camera unit to machine front side
Machine rear side
Step 2
Handle
Camera unit
53389-KMJ-00
Detaching screws of CX-axis cover front side
Machine front side
Step 3
Universal mask holder
Move into machine inside while pressing the button
Screws on front side
(two each on left and right)
CX-axis cover
PUSH
53390-KMJ-00
2. Monthly maintenance
3-10
Chapter 3 Periodic maintenance items
4
Move camera unit to machine rear side
by the work from rear side.
Move camera unit to machine rear side
grabbing its handle, by the work from rear
side.
5
Detach CX-axis cover by the work from
rear side.
1. Remove 4 screws of CX-axis cover rear side
using Phillips screwdriver.
2. Pull out to detach CX-axis cover.
6
Clean CX-axis ball screw.
1. Wipe off the grease or dirt on CX-axis ball
screw using a lint-free cloth.
2. Move camera unit to the opposite side and
wipe the rest part.
n
NOTE
Carefully wipe the lead grooves of the ball screw.
Additionally, make sure that any dirt is not remained.
7
Inject the grease to CX-axis ball screw.
Using a grease gun (standard nozzle), inject
the prescribed grease (NSL) to the grease
nipple of ball screw until the grease seep out
from the gap.
8
Wipe away excess grease.
1. Spread the grease by moving the camera
unit from left to right by hand.
2. Wipe away the excess grease from the both
ends of ball screw.
Moving camera unit and detaching CX-axis cover
Machine rear side
Step 4,5
4 screws on rear side
CX-axis cover
Handle
Camera unit
53391-KMJ-00
Cleaning CX-axis ball screw
Step 6
Lint-free cloth
Camera unit
CX-axis ball screw
53393-KMJ-00
Lubricating CX-axis ball screw
Step 7
Grease gun (standard nozzle)
Grease nipple
CX-axis
ball screw
53394-KMJ-00
2. Monthly maintenance
3-11
Chapter 3 Periodic maintenance items
9
Reattach CX-axis cover to its original
place.
1. Cover the bracket with the CX-axis cover
front side, by inserting CX-axis cover from
rear to frontward.
c
CAUTION
The CX-axis cover front side should cover on bracket.
2. Tighten the screws on CX-axis cover front
side (two each for left and right) using
Phillips screwdriver by the work from front
side.
3. Tighten four screws on CX-axis cover rear
side using Phillips screwdriver by the work
from rear side.
0
Reattach the center rear cover to its
original position using Phillips
screwdriver.
q
Clean CX-axis guide by the work from
front side.
1. Wipe away the grease or dirt on CX-axis
guide using a lint-free cloth.
2. Move the camera unit to the opposite side
and wipe away the rest part.
n
NOTE
Carefully wipe the guide grooves of the ball screw.
Additionally, make sure that any dirt is not remained.
w
Lubricate the prescribed grease (NSL)
to CX-axis guide using a grease gun
(bend type nozzle) to grease nipples
upper and lower area of guide.
The camera unit has four grease nipples,
two each on left and right side.
e
Wipe away excess grease.
1. Spread grease by moving the camera unit to
left and right.
2. Wipe off the excess grease from the guide
block of the guide.
Attaching CX-axis cover
Step 9
CX-axis coverCX-axis cover
CX-axis cover
Bracket
Bracket
53395-KMJ-00
Cleaning CX-axis guide
Step 11
Lint-free cloth
Camera unit
Cleaning unit
CX-axis guide
53396-KMJ-00
Lubricating CX-axis guide
Step 12
Grease gun
(bend type nozzle)
Grease nipples