00197454-01_AI_Portal_40mm_TwinVHF_SX12_de_en.pdf - 第94页
Brief Description Prerequisites 2.2.1 SIPLACE SX "Prepared" 94 Reconfiguration Kit Twin VHF with Gantry Reconfiguration Kit Twin VHF mit Por - 2.2 2 . 2 P r e r e q u is it e s Prerequisites ▪ This option is po…

Brief Description
2.1.6 Configurations Overview
Reconfiguration Kit Twin VHF with Gantry Reconfiguration Kit Twin VHF mit Portal 93
2.1.6.2
2.1.6.2 Stationary Cameras
Stationary Cameras
Stationary cameras on the SX1
SX1
1. Location 1 in outer position
2. Location 2 in inner position
3. Gantry 1
4. IC camera and/or FC camera/3D coplanarity module
(location 1)
You can only install either an FC camera or a 3D co
-
planarity module!
Stationary cameras on the SX2
SX2
1. Location 1 in outer position
2. Location 2 in outer position
3. Gantry 1
4. Gantry 2
5. IC camera and/or FC camera/3D coplanarity module
(location 1)
You can only install either an FC camera or a 3D co
-
planarity module!
6. IC camera (location 2)

Brief Description
Prerequisites 2.2.1 SIPLACE SX "Prepared"
94 Reconfiguration Kit Twin VHF with Gantry Reconfiguration Kit Twin VHF mit Por
-
2.2
2.2 Prerequisites
Prerequisites
▪ This option is possible for SX1, SX1prepared and SX2 machines.
▪ Serial number from Mxxx (higher input and output area)
Serial number from Lxxx restricted (max. 35 mm component height)
▪ Station software 707.0x
▪ SIPLACE Pro 11.1
▪ WPC5/6 - 45 mm (serial numbers from B3xxx/C3xxx)
This WPC is needed for feeding in components with heights up to 40 mm.
▪ A combination with the "Smart Pin Support" option is also possible. In this case, you need the appro
-
priately adapted pin picker.
2.2.1
2.2.1 SIPLACE SX "Prepared"
SIPLACE SX "Prepared"
The SIPLACE SX must be in the delivery state "Pre
-
pared".
This can be recognized by the presence of a trailing cable
(1) and the control unit for the main axes (Gantry Control
Unit (2)). This applies for the SIPLACE SX+ machine, in
order to retrofit gantry 1 at location 1 or for the SIPLACE
SX1 "Prepared", in order to retrofit gantry 2 at location 2.
The trailing cable is packed in a black plastic case and is
fixed at the side (1).
If this is not the case, your machine will need to be retro
-
fitted accordingly. Contact your SIPLACE Service team
for details.

Brief Description
2.2.1 SIPLACE SX "Prepared" Scope of Delivery
Reconfiguration Kit Twin VHF with Gantry Reconfiguration Kit Twin VHF mit Portal 95
2.3
2.3 Scope of Delivery
Scope of Delivery
Required parts:
▪ The option package VHF Twin 40 mm 70 N with Gantry" [00519986-xx] contains the following parts:
▪ Gantry carrier [00519814-03]
The gantry is supplied on a gantry carrier.
This gantry carrier must have at least function state 03 for use with the 40 mm gantry.
Quanti
-
ty
Designation Item No.
1 Camera screen assembly VHF-Twin head 03104859-xx
2 VHF-Twin module 03096701-xx
8 ISO4762-M4x14-8.8, galvanized, DSP 03069100-xx
1 GR gantry 40 mm 03096946-xx
1 PCB / B-Base adapter TWIN 03055517-xx
1 Nozzle set TwinHead 03019633-xx
1 Cable set TwinHead / B series 03065968-xx
2 Cable ties B = 2.5 mm L = 102 mm Panduit 00308458-xx
1 Blanking plug QSC-6H 00337891-xx
1 Blanking plug QSC-4H 00330249-xx
2 Standard nozzle 508 VHFM assembly 03094257-xx
1 ISO4762 - M3 x 6-A2-70 03042541-xx
1 Hose system TwinHead, VHF SX1/2 03106594-xx
2 HCU assembly 03054884-xx
▪ PCB camera type 34HU [03102921-xx]
(part of the gantry [03096946-xx], s.o.)
NOTICE!
This PCB camera differs from the standard camera. Re
-
member this e.g. when ordering spare parts.