00195813-07_IM_SSW_605.03_SP3_DE EN.pdf - 第10页
Installat ion Manual, Station Software Version 605.03 SP 3 12 /2012 E dition 10 of 46 - After an u pgrade to th e 605.x x software v ersion, cal ibrate the h eads of the D1 / D1i , D 2 / D2i and D4 / D4i m achines. The t…

Installation Manual, Station Software Version 605.03 SP3 12/2012 Edition
9 of 46
- After an upgrade to the 605.xx software version, calibrate the heads of the D1 / D1i, D2 / D2i and
D4 / D4i machines. The temperature compensation is activated for these machines.
3.3 Upgrade from the 601.x or 602.x Versions
When upgrading to the 605.xx software version, please consider following:
CAUTION
For upgrading to the 605.xx software version, please consider the installation manual
"Windows Embedded XP operating system for the MC German and English", item no.
[00195327-xx]. Therefore the standard media package [03054699-xx] is required.
- For SIPLACE X2, X3 and X4 machines with CPU 076 the following upgrade packages for the machine
controller are required:
- Upgrade package for SIPLACE X4 with CPU 076 (item no: [03029123S03] for computer upgrade to
CPU 086
- Upgrade package for SIPLACE X2 and X3 with CPU 076 (item no.: [03051831] for 128 MB memory
expansion
- Fix the temperature warning labels [03031926-01] at the C&P20 head (see the figure).

Installation Manual, Station Software Version 605.03 SP3 12/2012 Edition
10 of 46
- After an upgrade to the 605.xx software version, calibrate the heads of the D1 / D1i, D2 / D2i and
D4 / D4i machines. The temperature compensation is activated for these machines.

Installation Manual, Station Software Version 605.03 SP3 12/2012 Edition
11 of 46
4 Requirements
4.1 SIPLACE X-Series, D-Series and CA-Series Software Components
4.1.1 Station
The station uses the following operating system configuration
• Station computer: Microsoft Windows XP Professional
(including Service Pack 2 and most recent hotfixes)
• Machine controller: Microsoft Windows embedded XP (SP2)
4.1.2 Machine Components
The following versions of other machine components are required for the station software to function
correctly:
Station computer
SIPLACE Vision
Machine controller
SIPLACE Pro
Version 605.03 SP3 Version 414 Version 605.03 SP3 Version 8.0
Version 9.3
*)
*) SIPLACE Pro Version 9.3 is required if the type 30 component camera is used.
CAUTION
The functional statuses of the station computer, vision, machine controller and SIPLACE Pro
software must be compatible.