EDM V1.10 / Version Description Ausgabe 07/2011 Edition ● Undoing changed Visi on data: If you change an object's Vision data on an EDM Client and confirm this with OK but then undo this change, the message No objec…

100%1 / 76
EDM V1.10 / Version Description Ausgabe 07/2011 Edition
– If you change a lead group of a component shape, the changes are not displayed correctly
in the Difference Editor:
– If you change only one individual attribute, the whole lead group is marked as changed
(red) - not only this individual property.
– The Difference Editor cannot detect the correlation between the original lead group and
the changed lead group. The original lead group is marked in red and does not find a
counterpart in the changed lead group (right column). The changed lead group is listed
as a new group. This group does not find a counterpart in the original lead group (left
column) either.
– To correct this bug, you must click the
button to accept all changes. Do
not use the
button to accept only one of the lead groups. In this case, an
additional invalid lead group exists in the component shape.
– For technical reasons, it is not possible to merge fiducial MC and component shape LCU
numbers with the Extended Difference Editor.
● Deleting any of the following objects on the EDM Line Server will result in no notification being
sent to the Clearing Pool:
– Feeder inventory: Feeder
– Board: Fiducials and Inkspots
– Placement List: Precedence
– Table: Feeder
– Job: Recipe
– Production Schedule: Recipe
– Restriction: Restriction
– Station: Deleting Station Vision Data
● The Do not transfer optimization results option only describes the head steps generated by
the optimizer or the feasibility test at the Line Control GUI. If this option is activated, the
optimized setup will still be transferred. If, on the other hand, this option is not activated, ALL
data, including the optimized setup and head step data, will be transferred.
30
EDM V1.10 / Version Description Ausgabe 07/2011 Edition
● Undoing changed Vision data:
If you change an object's Vision data on an EDM Client and confirm this with OK but then undo
this change, the message No object data is displayed in the Clearing Pool on the master.
Figure 6-1: Clearing Pool on the master
Workaround:
► Create a filter in the EDM Configuration (Start – Programs –SIPLACE – SIPLACE EDM –
EDM Configuration) by choosing the Auto Reject tab and Vision Data Manager.
► Confirm this change with OK and save it.
► If the filter has already been created, it is sufficient to activate it by checking the check box.
► Finally, you have to start the EDM Service.
Figure 6-2: Creating a filter
31
EDM V1.10 / Version Description Ausgabe 07/2011 Edition
● If you have upgraded EDM and kept your settings from a previous version, you should
manually remove one line at the very end of EDM.config.
► Remove the following line:
<add key="EdeUserControlOverride"
value"Siemens.SiplacePro.EDM.EdeExtension.DiffEditViewer,
EdeExtension" />
● Feeder inventories and restriction objects
It is possible to edit the feeder inventory at the EDM Line Server (by adjusting the filter
configuration).
CAUTION
– If you accept changes in the Clearing Pool, you overwrite existing definitions and
previously accepted changes. It is therefore strongly recommended to use a
separate feeder inventory object for each SIPLACE line.
– Similar problems could occur for restrictions on SIPLACE Pro Desk. It is therefore
recommended that you activate the filter for optimizer restrictions Disable all
changes to Optimizer Restrictions.
● Encoding of configuration files (Unicode)
Some editors for text files or XML files do not follow the Unicode encoding scheme for
configuration files. If you use characters that do not belong to the standard 7-bit ASCII
character set (i.e. German umlauts in the EDM Client comment fields), make sure that you save
the configuration files as Unicode (e.g. UTF8). The standard Microsoft editor notepad.exe
provides this option in the Save As… dialog box.
● Restoring objects with pending changes in EDM Clearing Pool
Customized workflows may need to be modified to benefit from this feature.
● Selecting multiple objects
– Multiple objects cannot be compared.
– One and the same object cannot be imported from two different lines – in this case no
object is imported.
– A currently running import operation cannot be canceled.
32