4OM-1075-002.pdf - 第141页
Error ID Item Description 0a0201 Nozzle Change #1 Axis Data 0a0202 Nozzle Change #1 Axis Data 0a0203 Nozzle Change #1 Axis Data (Cause 1) Self-Diagnostics Error Message (Remedy 1) Zero all axes and re-start the operation…

Error ID Item Description
09060f Head Rotational #2 Axis Error Error1 (No Factor)
090610 Head Rotational #2 Axis Error Error2 (No Factor)
090611 Head Rotational #2 Axis Error Emergency stop (EXT1) when servo on
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
090701 Head Rotational #2 Axis Interlock Servo alarm (Interlock board)
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
0a0101 Nozzle Change #1 Axis Origin Nozzle Cam Origin Sensor Detection Time-Out
0a0102 Nozzle Change #1 Axis Origin
0a0103 Nozzle Change #1 Axis Origin
0a0110 Nozzle Change #1 Axis Origin
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
3.3 Error IDs and Remedial Procedures
0107-001 2-51 AHB01ETRP

Error ID Item Description
0a0201 Nozzle Change #1 Axis Data
0a0202 Nozzle Change #1 Axis Data
0a0203 Nozzle Change #1 Axis Data
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
0a0301 Nozzle Change #1 Communication
0a0302 Nozzle Change #1 Communication
0a0303 Nozzle Change #1 Communication
0a0304 Nozzle Change #1 Communication
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
0a0401 Nozzle Change #1 Change Nozzle Change failed.
0a0402 Nozzle Change #1 Change
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
3.3 Error IDs and Remedial Procedures
01 12-002 2-52 AHB01ETRP

Error ID Item Description
0a0601 Nozzle Change #1 Interlock Step out was detected.
0a0602 Nozzle Change #1 Interlock
0a0603 Nozzle Change #1 Interlock
0a0604 Nozzle Change #1 Interlock
0a0605 Nozzle Change #1 Interlock
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
0a0701 Nozzle Change #1 Operation Error Nozzle Change result error.
0a0702 Nozzle Change #1 Operation Error Nozzle Change result error.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
0b0101 Nozzle Change #2 Axis Origin Nozzle Cam Origin Sensor Detection Time-Out
0b0102 Nozzle Change #2 Axis Origin Motor Origin Sensor Detection Time-Out
0b0103 Nozzle Change #2 Axis Origin Head push sensor error.
0b0110 Nozzle Change #2 Axis Origin
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
3.3 Error IDs and Remedial Procedures
0308-002 2-52-1 AHB01ETRP