4OM-1075-002.pdf - 第165页

Error ID Item Description 120401 T V # 2 Axis Limit 120402 T V # 2 Axis Limit (Cause 1) The X1 axis might have overrun due to generation of noises, overcurrent, etc. The sensor may be defective. (Remedy 1) Zero all axes …

100%1 / 299
Error ID Item Description
120109 TV #2 Axis Origin Pallet detected. (5402)
12010a TV #2 Axis Origin Operation not completed normally. (5403)
12010b TV #2 Axis Origin Zeroing not completed within specified time. (5404)
12010c TV #2 Axis Origin Pallet not detected. (5501)
12010d TV #2 Axis Origin Pallet installation error not detected within specified
time. (5502)
12010e TV #2 Axis Origin Pallet installation error detected before destinatation.
(5601)
12010f TV #2 Axis Origin Pallet not detected. (5701)
120110 TV #2 Axis Origin Operation not completed normally. (5702)
120111 TV #2 Axis Origin Operation not completed within specified time. (5703)
120114 TV #2 Axis Origin Rack shutter not closed within specified time. (5704)
120115 TV #2 Axis Origin Origin detected after end of zeroing operation.
(BPH511) (5901)
120117 TV #2 Axis Origin Operation not completed normally. (5902)
120118 TV #2 Axis Origin The limit sensors (BPH513) detected the limit. (5903)
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
120201 TV #2 Axis Timing
120301 TV #2 Axis Data
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
3.3 Error IDs and Remedial Procedures
0206-002 2-72 AHB01ETRP
Error ID Item Description
120401 TV #2 Axis Limit
120402 TV #2 Axis Limit
(Cause 1) The X1 axis might have overrun due to generation of noises, overcurrent, etc.
The sensor may be defective.
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
120601 TV #2 Axis Interlock Driver Alarm
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service per-
sonnel for the remedy.
120602 TV #2 Axis Interlock Pick-Up Error Detection (Upper, 16.5 mm or more);
BPH518
120603 TV #2 Axis Interlock Pick-Up Error Detection (Lower, 8.0 mm or more);
BPH517
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Remove the mispicked component on the tray.
120604 TV #2 Axis Interlock Pass-line Interlock
120605 TV #2 Axis Interlock Pick-Up Error Detection (Upper, 28.0 mm or more);
BPH522
120606 TV #2 Axis Interlock
120607 TV #2 Axis Interlock
120608 TV #2 Axis Interlock Overload Safety Shutoff Detection (Safety Relay)
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
3.3 Error IDs and Remedial Procedures
0308-004 2-73 AHB01ETRP
Error ID Item Description
121001 TV #2 Precheck Zeroing not completed within specified time. (Current
Position Indefinite)
121002 TV #2 Precheck Pallet not drawn normally.
121003 TV #2 Precheck Multi-layer tray feeder door opened. (K504)
121004 TV #2 Precheck Safty relay off; K502
121005 TV #2 Precheck Pallet installation error detected (on operator or
drawing side).; BPH504/505
121006 TV #2 Precheck Rack shutter opened.; BPS502/504
121007 TV #2 Precheck Pallet chuck opened.; BPS512
121008 TV #2 Precheck L1 Axis Zeroing not completed
121009 TV #2 Precheck
12100a TV #2 Precheck
12100b TV #2 Precheck Pallet detected.; BPS514
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service per-
sonnel for the remedy.
12100c TV #2 Precheck
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Remove the mispicked component on the tray.
12100f TV #2 Precheck Incorrect No. of Drawing Step
122005 TV #2 Precheck Pallet installation error detected on operator side.;
BPH505
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
3.3 Error IDs and Remedial Procedures
0206-002 2-74 AHB01ETRP