4OM-1075-002.pdf - 第285页

Error ID Item Description 02 ** 3300 ** Error in Edge Detection 02 ** 3301 ** Error in Edge Detection Some edges cannot be detected because they are hidden by the nozzle. 02 ** 3302 ** Error in Edge Detection No Edge Det…

100%1 / 299
Error ID Item Description
02 ** 3100 ** Error in Corner Detection
02 ** 3101 ** Error in Corner Detection More than two corners of a component are hidden
by the protruded nozzle.
02 ** 3102 ** Error in Corner Detection Corner Not Detected.
(Cause 1) The pick-up position has shifted from the specified one in the X direction.
Fig.4B51
(Cause 2) The tapered part of the vacuum nozzle end or the diffusion plate is stained.
Fig.4B52
(Remedy 1) Check the components and the feeders.
(Remedy 2) Clean the vacuum nozzle end or the diffusion plate.
02 ** 3200 ** Error in Center of Gravity Detection
02 ** 3201 ** Error in Center of Gravity Detection The component shape (size) is not applicable.
02 ** 3202 ** Error in Center of Gravity Detection Failed in Corner Detection.
02 ** 3203 ** Error in Center of Gravity Detection Failed in Center of Gravity Detection.
(Cause 1) The selected component does not match the nozzle.
(Cause 2) The component is bent due to weak vacuum suction force.
(Remedy 1) Check the selected component and the vacuum nozzle.
(Remedy 2) Check the vacuum pressure.
4.3 Recognition Error IDs and Remedial Procedures
Vacuum Nozzle
Component
Dirty Spots
Component
Vacuum Nozzle
0308-001 2-143-1 AHB01ETRP
Error ID Item Description
02 ** 3300 ** Error in Edge Detection
02 ** 3301 ** Error in Edge Detection Some edges cannot be detected because they are
hidden by the nozzle.
02 ** 3302 ** Error in Edge Detection No Edge Detected.
02 ** 3303 ** Error in Edge Detection Upper Edge Not Detected.
02 ** 3304 ** Error in Edge Detection Left Edge Not Detected.
02 ** 3305 ** Error in Edge Detection Lower Edge Not Detected.
02 ** 3306 ** Error in Edge Detection Right Edge Not Detected.
(Cause 1) The selected component does not match the nozzle.
(Cause 2) Wrong parameters (edge data) are set for the selected component in the
component library data.
(Cause 3) The tapered part of the vacuum nozzle end or the diffusion plate is stained.
Fig. 4B53
(Remedy 1) Check the selected component and the vacuum nozzle.
(Remedy 2) Check the edge condition of the selected component and the component
library data.
If wrong parameters are set in the component library data, correct them.
(Remedy 3) Clean the vacuum nozzle end or the diffusion plate.
4.3 Recognition Error IDs and Remedial Procedures
0308-004 2-144 AHB01ETRP
Dirty Spots
Component
Vacuum Nozzle
Error ID Item Description
02 ** 3400 ** Error in Line Detection
02 ** 3401 ** Error in Line Detection Some linear edges cannot be detected they are
hidden by the nozzle.
02 ** 3402 ** Error in Line Detection No Linear Edge Detected.
02 ** 3403 ** Error in Line Detection The Deteted Linear Edge Position Does Not The
Position Data.
02 ** 3500 ** Error in Lead Detection
02 ** 3501 ** Error in Lead Detection Some leads cannot be detected because they are
hidden by the nozzle.
02 ** 3502 ** Error in Lead Detection No Lead Detected.
02 ** 3503 ** Error in Lead Detection Corner of Leads Not Detected.
02 ** 3504 ** Error in Lead Detection Ends of Leads Not Detected.
02 ** 3505 ** Error in Lead Detection Ends of Arrayed Leads Not Detected.
02 ** 3506 ** Error in Lead Detection Lead Edges of Corner Not Detected.
02 ** 3507 ** Error in Lead Detection Leads of Corner Not Detected.
02 ** 3508 ** Error in Lead Detection The number of leads at the detected corner is
smaller than the set value.
02 ** 3509 ** Error in Lead Detection Incorrect Lead-to-Lead Distance at Detected Cor-
ner.
02 ** 3510 ** Error in Lead Detection Incorrect Lead-to-Lead Angle at Detected Corner.
02 ** 3512 ** Error in Lead Detection The detected number of leads is smaller than the
set value.
02 ** 3513 ** Error in Lead Detection The detected number of leads is larger than the
set value.
02 ** 3514 ** Error in Lead Detection Incorrect Detected Group-to-Group Distance.
02 ** 3515 ** Error in Lead Detection The Detected Lead Position Does Not Match the
Position Data.
(Cause 1) The results of the lead detection differ from the parameters specified in the
component library data for the selected components.
(Remedy 1) Check the leads of the selected component and the component library
data.
If wrong parameters are set in the component library data, correct them.
4.3 Recognition Error IDs and Remedial Procedures
0308-003 2-145 AHB01ETRP