4OM-1075-002.pdf - 第85页

(Remedy 3) • W ait until the program is started completely . • Cancel the "Emergency Stop" mode to reset the machine to its normal condition. Refer to "2.3 [EMERGENCY STOP] Button Pressed" for details…

100%1 / 299
2. Easy Troubleshooting
Described below is how to troubleshoot simple problems that can be
solved by the machine operator.
When the operator cannot solve a problem, he/she should get in con-
tact with the supervisor (a person in charge of machine management).
2.1 Power Operation Impossible
Table 4B2
Symptom When the [POWER ON] button on the operation panel is pressed, the ma-
chine is not powered.
Cause (Cause 1) The [POWER ON] button on the operation panel is not held down
for more than 1 seconds.
(Cause 2) The power breaker is set to "OFF".
(Cause 3) The lamp of the [POWER ON] button on the operation panel illumi-
nates in red.
(Cause 4) The power breaker is tripped.
Remedy (Remedy 1) Hold down the [POWER ON] button on the front or the rear op-
eration panel for more than 1 seconds.
When power is supplied, the lamp of the [POWER ON] button illumi-
nates in yellowish green.
Fig. 4B4 Front Operation Panel
(Remedy 2) Set the power breaker to "ON".
Fig. 4B5
Turn on or off the working lamp switch beside the front or the rear
operation panel. If the working spot lamp illuminates or extin-
guishes, it indicates that the machine is powered.
2. Easy Troubleshooting
0308-004 2-6 AHB01ETRP
MULTI FUNCTIONAL MOUNTER
STOP
LOCK
OPERATION
RUN SETUP
START
ENABLE
PNL CHANGE
READY
POWER ON
EMERGENCY
(Remedy 3) Wait until the program is started completely.
Cancel the "Emergency Stop" mode to reset the machine to
its normal condition.
Refer to "2.3 [EMERGENCY STOP] Button Pressed" for
details.
Close the front or the rear safety door.
Set the main air pressure to the specified one "0.4 MPa (4.1
kgf/cm
2
)".
Refer to "1.1.1 Confirmation of Power Supply and Air Pres-
sure" in "Section 3" of "Vol. 1" for details.
(Remedy 4) Turn on the power breaker while holding down the [RESET] but-
ton (red).
2.2 Nothing Displayed on Touch Screen
Table 4B2-1
Symptom Nothing is displayed on the touch screen.
Cause (Cause 1) The screen saver function is activated.
(Cause 2) Power is not supplied from the source.
Remedy (Remedy 1) Touch a part of the touch screen. The foreground activities will
occur in any running application.
(Remedy 2) Refer to "2.1 Power Operation Impossible" for details and follow
the remedial procedure.
0206-003 2-7 AHB01ETRP
2.1 Power Operation Impossible
2.3 [EMERGENCY STOP] Button Pressed
2.3.1 During Automatic Operation
Table 4B3
Symptom (1) The LED of the [POWER ON] button illuminates in red and the following
window opens.
Fig. 4B6
Cause (1) An [EMERGENCY STOP] button was pressed.
Remedy (1) Check the displayed contents.
(2) Press the [RETURN] button.
(3) Remove the cause of the problem that prompted the operator to press the
[EMERGENCY STOP] button.
(4) Check the feeders.
When the component to be picked up is left in the supply position, remove
it.
(5) Check if there is a component which has dropped inside the machine.
(6) Check whether or not the P.C.B. in the middle of component placement is
located correctly (not out of the P.C.B. positioning section) and the compo-
nents are placed normally (not dispersed).
(7) Turn the [EMERGENCY STOP] button clockwise to release the locked
condition.
(8) Hold down the [POWER ON] button for more than 1 second to re-supply
power to the machine.
When the LED of the [POWER ON] button illuminates in yellowish green,
it indicates that the power is supplied to the machine.
When the LED is kept red, re-check the cause and remove it.
(9) Press the [ALL] button (entitled "ZERO") in the "AUTO OPN." window. In 2
seconds, press the [ENABLE] button on the operation panel to zero all
devices.
0206-003 2-8 AHB01ETRP
2.3 [EMERGENCY STOP] Button Pressed