4OM-1075-002.pdf - 第263页

Error ID Item Description 01 39 2 1 1001 An improper parameter is specified as ----- "Component shape". 01 39 2 1 1002 "Mold Size T olerance X" is larger than "Mold ----- Size X". 01 39 2 1 …

100%1 / 299
Error ID Item Description
01 30 2 00000 The transferred magnification does not meet the -----
specifications of the machine.
(Cause 1) The magnification exceeding the specified one was transferred.
(Remedy 1) Contact our service personnel for details.
01 30 3 00001 Error in "Camera MAGNIFICATION X or
MAGNIFICATION Y" Data.
(Cause 1) Wrong parameters are set.
(Remedy 1) Set correct parameters.
01 38 2 00000 Unavailable fiducial mark code was set.
01 38 2 00001 "Mark Size D2" is too big, compared with "D1".
01 38 2 00002 "Mark Size D3" is too big, compared with "D1".
01 38 2 00003 "Mark Size D2" is too big, comapred with "D3".
01 38 2 00004 "Window Size" is smaller than "Mark Size".
01 38 2 00005 "Mark Size D2" is not set.
01 38 2 00006 "Mark Size D3" is not set.
01 38 3 00001 Error in "P.C.B Recognition Mark Data MarkSize
D1 or D2 or D3" Data.
01 38 3 00003 Error in "P.C.B Recognition Mark Data Window
Size" Data.
(Cause 1) Wrong parameters are set for the P.E.C. recognition function.
(Remedy 1) Refer to "Section 2 Pattern Program" in "Vol. 3" for details and set cor-
rect parameters.
0206-002 2-125 AHB01ETRP
4.3 Recognition Error IDs and Remedial Procedures
Error ID Item Description
01 39 2 11001 An improper parameter is specified as -----
"Component shape".
01 39 2 11002 "Mold Size Tolerance X" is larger than "Mold -----
Size X".
01 39 2 11003 "Mold Size Tolerance Y" is larger than "Mold -----
Size Y".
01 39 2 11004 "Outward Length Tolerances" are larger than -----
"Outward Length".
01 39 2 12001 The total of "Corner 1 Dim X" and "Corner 4 Dim -----
X" is larger than "Mold Size X".
01 39 2 12002 The total of "Corner 1 Dim Y" and "Corner 2 Dim -----
Y" is larger than "Mold Size Y".
01 39 2 12003 The total of "Corner 2 Dim X" and "Corner 3 Dim -----
X" is larger than "Mold Size X".
01 39 2 12004 The total of "Corner 3 Dim Y" and "Corner 4 Dim -----
Y" is larger than "Mold Size Y".
01 39 2 12005 "Electrode Size" is larger than half of "Mold -----
Size X".
01 39 2 12006 "# of Linear Edges" is improper.
01 39 2 13001 "# of Types" (lead data) is improper. -----
01 39 2 13002 "# of Groups" (lead data) is improper. -----
01 39 2 13003 The total of "# of Leads" (lead data) is too small. -----
01 39 2 13004 "No Detection" is set in all "Insp Condtn" text -----
boxes.
01 39 2 13005 "Lead Type No." in "Lead Group 1" is improper. -----
01 39 2 13006 "Lead Type No." in "Lead Group 2" is improper. -----
01 39 2 13007 "Lead Type No." in "Lead Group 3" is improper. -----
01 39 2 13008 "Lead Type No." in "Lead Group 4" is improper. -----
01 39 2 13009 "Lead Type No." in "Lead Group 5" is improper. -----
01 39 2 13010 "Lead Type No." in "Lead Group 6" is improper. -----
(Cause 1) Wrong parameters are set.
(Remedy 1) Set correct parameters.
4.3 Recognition Error IDs and Remedial Procedures
0206-002 2-126 AHB01ETRP
Error ID Item Description
01 39 2 13011 "Lead Type No." in "Lead Group 7" is improper. -----
01 39 2 13012 "Lead Type No." in "Lead Group 8" is improper. -----
01 39 2 13013 "Lead Pitch" in "Lead Group 1" is smaller than -----
"Lead Width".
01 39 2 13014 "Lead Pitch" in "Lead Group 2" is smaller than -----
"Lead Width".
01 39 2 13015 "Lead Pitch" in "Lead Group 3" is smaller than -----
"Lead Width".
01 39 2 13016 "Lead Pitch" in "Lead Group 4" is smaller than -----
"Lead Width".
01 39 2 13017 "Lead Pitch" in "Lead Group 5" is smaller than -----
"Lead Width".
01 39 2 13018 "Lead Pitch" in "Lead Group 6" is smaller than -----
"Lead Width".
01 39 2 13019 "Lead Pitch" in "Lead Group 7" is smaller than -----
"Lead Width".
01 39 2 13020 "Lead Pitch" in "Lead Group 8" is smaller than -----
"Lead Width".
01 39 2 13021 "Missing Lead Start" in "Lead Group 1" is too large. -----
01 39 2 13022 "Missing Lead Start" in "Lead Group 2" is too large. -----
01 39 2 13023 "Missing Lead Start" in "Lead Group 3" is too large. -----
01 39 2 13024 "Missing Lead Start" in "Lead Group 4" is too large. -----
(Cause 1) Wrong parameters are set.
(Remedy 1) Set correct parameters.
0206-003 2-127 AHB01ETRP
4.3 Recognition Error IDs and Remedial Procedures