4OM-1075-002.pdf - 第142页

Error ID Item Description 0a0601 Nozzle Change #1 Interlock Step out was detected. 0a0602 Nozzle Change #1 Interlock 0a0603 Nozzle Change #1 Interlock 0a0604 Nozzle Change #1 Interlock 0a0605 Nozzle Change #1 Interlock (…

100%1 / 299
Error ID Item Description
0a0201 Nozzle Change #1 Axis Data
0a0202 Nozzle Change #1 Axis Data
0a0203 Nozzle Change #1 Axis Data
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
0a0301 Nozzle Change #1 Communication
0a0302 Nozzle Change #1 Communication
0a0303 Nozzle Change #1 Communication
0a0304 Nozzle Change #1 Communication
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
0a0401 Nozzle Change #1 Change Nozzle Change failed.
0a0402 Nozzle Change #1 Change
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
3.3 Error IDs and Remedial Procedures
01 12-002 2-52 AHB01ETRP
Error ID Item Description
0a0601 Nozzle Change #1 Interlock Step out was detected.
0a0602 Nozzle Change #1 Interlock
0a0603 Nozzle Change #1 Interlock
0a0604 Nozzle Change #1 Interlock
0a0605 Nozzle Change #1 Interlock
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
0a0701 Nozzle Change #1 Operation Error Nozzle Change result error.
0a0702 Nozzle Change #1 Operation Error Nozzle Change result error.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
0b0101 Nozzle Change #2 Axis Origin Nozzle Cam Origin Sensor Detection Time-Out
0b0102 Nozzle Change #2 Axis Origin Motor Origin Sensor Detection Time-Out
0b0103 Nozzle Change #2 Axis Origin Head push sensor error.
0b0110 Nozzle Change #2 Axis Origin
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
3.3 Error IDs and Remedial Procedures
0308-002 2-52-1 AHB01ETRP
Error ID Item Description
0b0201 Nozzle Change #2 Axis Data
0b0202 Nozzle Change #2 Axis Data
0b0203 Nozzle Change #2 Axis Data
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
0b0301 Nozzle Change #2 Communication
0b0302 Nozzle Change #2 Communication
0b0303 Nozzle Change #2 Communication
0b0304 Nozzle Change #2 Communication
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
0b0401 Nozzle Change #2 Change Nozzle Change failed.
0b0402 Nozzle Change #2 Change
(Cause 1) Self-Diagnostics Error Message
(Cause 2) It can be assumed that the nozzle change cam in the head section might be worn
out.
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
(Remedy 2) Refer to "1.4.1 Replacement of Nozzle Change Cam" in "Section 1" and replace
the cam with a new one.
3.3 Error IDs and Remedial Procedures
0206-003 2-53 AHB01ETRP