0308-002 2-105-1 AHB01ETRP 3.3 Error IDs and Remedial Procedures Error ID Item Description 6b1001 V .Bend Detection System Error Syetem error . (1000) 6b101 1 V .Bend Detection System Error Memory error in unit.(1010) 6b…

Error ID Item Description
690601 Nozzle Replace Interlock Nozzle was not seated properly in Nozzle Stocker
(B1).
690602 Nozzle Replace Interlock Nozzle was not seated properly in Nozzle Stocker
(B2).
690603 Nozzle Replace Interlock Nozzle was not seated properly in Nozzle Stocker
(A1) (Option).
690604 Nozzle Replace Interlock Nozzle was not seated properly in Nozzle Stocker
(A2) (Option).
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
6a0101 Defective Unit P.C.B. Bad Marks Detected on All Unit PCBs
6a0102
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Check the P.C.B. and determine whether or not the operation should be contin-
ued.
6b0101 V.Bend Detection System Error Communication time-out.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Check the lead coplanarity unit PC and the cable connected to the main body.
(RS-232C Cable)
6b0102 V.Bend Detection System Error Error command.
6b0103 V.Bend Detection System Error Error received data.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service per-
sonnel for the remedy.
3.3 Error IDs and Remedial Procedures
0308-004 2-105 AHB01ETRP

0308-002 2-105-1 AHB01ETRP
3.3 Error IDs and Remedial Procedures
Error ID Item Description
6b1001 V.Bend Detection System Error Syetem error. (1000)
6b1011 V.Bend Detection System Error Memory error in unit.(1010)
6b1061 V.Bend Detection System Error Laser error.(1060)
6b1071 V.Bend Detection System Error Memory error insensor section.(1070)
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Shut down the machine and power it up again.
6b1081 V.Bend Detection System Error Sensor cable not connected. (1080)
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Check the connection between the lead coplanarity unit PC and the sensor
head.
6b1091 V.Bend Detection System Error Unsteady mortor rotaion in sensor. (1090)
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Check the connection of the power cable to the sensor head.
6b1101 V.Bend Detection System Error Laser OFF. (1100)
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Shut down the machine and power it up again.
6b2001 V.Bend Detection Operation Error
6b2011 V.Bend Detection Operation Error Wrong level adjustment. (2010)
6b2031 V.Bend Detection Operation Error Wrong component no. (2030)
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Shut down the machine and power it up again.

Error ID Item Description
6b2041 V.Bend Detection Operation Error Measurement Start Signal Not Recognized. (2040)
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Check the lead coplanarity unit PC and the cable connected to the main body.
(Measurement Start Signal)
6b2051 V.Bend Detection Operation Error Illegal Command Parameter. (2050)
6b2061 V.Bend Detection Operation Error Unknown Reference Component Data. (2060)
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Shut down the machine and power it up again.
6b2071 V.Bend Detection Operation Error Improper Measurement Mode. (2070)
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Make the measurement in the normal mode.
6b3001 V.Bend Detection Operation Error Coplanarity Error! (3000)
6b3011 V.Bend Detection Operation Error Terminal Misregistration Error! (3010)
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service per-
sonnel for the remedy.
0308-002 2-105-2 AHB01ETRP
3.3 Error IDs and Remedial Procedures