NR_Mechanischer_Stopper.pdf - 第186页

Assembly Instructions PCB Stopper Sin gle Conveyor SIPLACE S-27HM / HS-60 / D4 / D3 / HF- / X-Series Edition 06/2007 186 O Clean the conveyor tub in the a rea of the guide strip with a lint-free clo th moistened with eth…

100%1 / 238
Assembly Instructions PCB Stopper Single Conveyor SIPLACE S-27HM / HS-60 / D4 / D3 / HF- / X-Series
Edition 06/2007
185
O Place the width adjustment in the center.
To do this, move the belt of the side adjustment by hand. This is located on the outside of con-
veyor track 1 of the lifting table.
Fig. 159 Belt of width adjustment
O Screw the guide rail holders to the lifting table on the left and right, each with two cylinder head
bolts with hexagon socket head M4 x 40 DIN 912.
Note:
The holders on the left and right are identical in shape but are installed at 180 degrees to each
other. Make sure when installing them that the projection of each holder lies on the external side
of the lifting table.
The length of the holders [03037444-xx] is 54 mm on the S-27HM.
Fig. 160 Holders on the lifting table
Belt of
width adjustment
Width adjustment
Holder
right
Con-
veyor
track 1
Holder
left
Con-
veyor
track 2
Lifting table
Assembly Instructions PCB Stopper Single Conveyor SIPLACE S-27HM / HS-60 / D4 / D3 / HF- / X-Series
Edition 06/2007
186
O Clean the conveyor tub in the area of the guide strip with a lint-free cloth moistened with ethyl
alcohol so that you have a clean sticking surface.
O To make cable laying easier later, bundle the hoses and cables of each stopper with a few ca-
ble ties.
O Lay the guide rail in the lifting table diagonally.
Fig. 161 Guide rail with stopper in conveyor track 1
O Push the stopper with the high distance block onto the guide rail in conveyor track 1.
O Push the stopper with the low distance block onto the guide rail in conveyor track 2.
O Mark the following distances for the trailing cable distance blocks on the floor of the conveyor
mounting tub with a pen.
Fig. 162 Distances for the trailing cable distance blocks (S-27HM)
Conveyor track 2 Conveyor track 1
Distance block for energy chain
Left
conveyor side
Right
conveyor side
360 mm 150 mm
460 mm 50 mm
Transport direction
Assembly Instructions PCB Stopper Single Conveyor SIPLACE S-27HM / HS-60 / D4 / D3 / HF- / X-Series
Edition 06/2007
187
O Position the guide rail with the stoppers at its final position on the holders, but don't screw it
tight yet.
O Hold each of the trailing cable distance blocks in turn at the marked position with your hand
and check that the stoppers can move freely to the end.
14
Make sure that the trailing cable stands vertically to the stopper and does not collide with the belt
of the width adjustment. The stopper must subsequently move freely on the rail over the entire
conveyor width, and the trailing cables must not tilt to the side. 14
Fig. 163 Trailing cables
O When the trailing cables are in their final position, mark the exact positions of the trailing cable
distance blocks with a pen. Now stick the trailing cable distance blocks onto the marked posi-
tions with the double-sided adhesive tape. Make sure you keep the sticking surfaces clean and
do not touch them.
O Now affix the guide rail to the holders with two cylinder head bolts with hexagon socket head
M5 x 20 (DIN 912, ISO 4762).
Fig. 164 Attaching the guide rail (here: Conveyor track 1)
Guide rail
Screw for fixing the guide
rail to the holder (half hid-
den)
Holder