NR_Mechanischer_Stopper.pdf - 第204页
Assembly Instructions PCB Stopper Sin gle Conveyor SIPLACE S-27HM / HS-60 / D4 / D3 / HF- / X-Series Edition 06/2007 204 15.2.2 Inst allati on of the stoppers Caution: Before the stopper is mounted in the mach ine, it sh…

Assembly Instructions PCB Stopper Single Conveyor SIPLACE S-27HM / HS-60 / D4 / D3 / HF- / X-Series
Edition 06/2007
203
15.2 Installation at placement area 1
The surfaces on which the self-adhesive cable clamps, solenoid valves, etc., are to be stuck later
should be cleaned first with a lint-free cloth moistened with ethyl alcohol. 15
15
15.2.1 Installation of the holders
O Install the "Guide strip holders PA1 HF" [03032321-xx] (Fig. 183) for the guide strip of the PCB
stopper. The holders are installed so that they are flush at the top with the lateral frames of the
lifting table. To prevent the holder from twisting, the lateral shoulder of the holder must lie
against the outside of the frames.
Fasten each of the holders with a cylinder head bolt with hexagon socket head
M4 x 40-DIN 912.
Fig. 183 Holders
Holders

Assembly Instructions PCB Stopper Single Conveyor SIPLACE S-27HM / HS-60 / D4 / D3 / HF- / X-Series
Edition 06/2007
204
15.2.2 Installation of the stoppers
Caution: Before the stopper is mounted in the machine, it should be adjusted with the guide strip
and the shims. Care should be taken to ensure that the stopper is not too loose or too tight. The
graduation of the shims is 0.1mm.
(See also Fig. 209, page - 232.)
O Clean the conveyor tub in the area of the guide strip with a lint-free cloth moistened with ethyl
alcohol.
O Push the guide strip into the conveyor from outside.
O Push the stopper units carefully onto the guide strip.
Be careful not to damage the sliding guides when pushing onto the guide rail!
Fig. 184 Push the guide strip into the conveyor

Assembly Instructions PCB Stopper Single Conveyor SIPLACE S-27HM / HS-60 / D4 / D3 / HF- / X-Series
Edition 06/2007
205
O Attach the guide strip to the holders with two cylinder head bolts (hexagon socket head
M5 x 20 DIN 912).
O Test whether the trailing cable can move freely by pushing it to the end from the side.
O For the HF-/X-Series (mounting tub 604 mm) with dual and single conveyor, the following dis-
tances must be observed:
Fig. 185 Distances for the trailing cable distance blocks (HF, X-Series)
For a dual conveyor, stick an additional "Distance block for energy chain, complete" in the mid-
dle between the two energy chain distance blocks for better movement of the trailing cable.
[03043432-xx]. 15
O Using the adhesive tape, stick the distance block of the trailing cable onto the mounting tub
under the second conveyor side parallel to the guide rail (or to the width adjustment) in such a
way that the trailing cable stands vertical when the guide rail is installed.
Conveyor track 2 Conveyor track 1
Distance block for energy chain
Left
conveyor side
Right
conveyor side
340 mm 260 mm
440 mm
160 mm
Transport direction
Left side of
mounting tub
Right side of
mounting tub
604 mm