SussPA300UserGuide.pdf - 第23页
22 SUSS / PA300 / User Manual / M10-121841-00 / February 2002 4.4 Joystick Controller For further explanation please refer to section 7.3. The Joystick Controller provides remote control of all probe system motorized sta…

SUSS / PA300 / User Manual / M10-121841-00 / February 2002
21
4.2.6 Accessories
Accessories such as the computer table, control panel and mouse should be supplied
by the customer. For suggestions, measurements and further optional devices please
see the Ergonomic Information Table in the appendix.
When computer monitors are to be used, the size is to be determined by the customer
(see Ergonomic Information Table in the appendix).
The customer must also determine the location of the hand controls and whether the
machine is to be used in a standing or sitting position (see Ergonomic Information
Table in the appendix).
4.3 Emergency Off (EMO) System
See section 7.2.2
4.3.1 Main Power Switch on Electronics Rack
The main power switch on the electronics rack is also an EMO system. This is shown
through a red grip on a yellow background. After use all movement is stopped and the
system is completely without power. Positions are lost and the system must be re-
initialized.
Main Power Switch (EMO)
Power On Lamp
On Button (green)
Off Button (red)
4.3.2 EMO Switch on Probe Station
The EMO system when activated immediately stops all system movement and removes
all small voltages except the 24 VAC EMO power supply.
The EMO button is for emergency use only to prevent injury, or damage to equipment
or the device under test. Normal shutdown of the system saves positioning information
that is used during the next system power-up. The use of the EMO system may corrupt
the positioning information. Running the Prober Initialization program will be necessary
for normal system operation to be restored. Please refer to the ProberBench manual.
The standard EMO actuator is red on a yellow background and is located on the right
front corner of the mechanic. Optional buttons may be located on a light tight enclosure,
isolation table or instrument rack. After use, latching buttons should be released by
pulling outward on the button, and the system can then be switched on again by pushing
the green button on the ProberBench electronics

22
SUSS / PA300 / User Manual / M10-121841-00 / February 2002
4.4 Joystick Controller
For further explanation please refer to section 7.3.
The Joystick Controller provides remote control of all probe system motorized stages
including the wafer chuck, microscope, ProbeHeads and platen. The most common
functions such as load, vacuum, go and set home, contact and two-point alignment
are also provided. It can be used with or without a PC.
Joystick
(X, Y movement of
chuck or scope)
Mode key
Position & function displays

SUSS / PA300 / User Manual / M10-121841-00 / February 2002
23
4.5 Electronics Rack
Main
m
i
c
r
o
c
o
n
t
r
o
l
l
e
r
b
o
a
r
d
Misc
.
O
u
t
p
u
t
i
n
t
e
r
f
a
c
e
c
a
r
d
(
C
4
)
Main
f
u
s
e
s
(
F
1
/
F
2
)
Flex
i
b
l
e
g
r
o
u
n
d
c
o
n
t
a
c
t
s
Main
p
o
w
e
r
s
u
p
p
l
y
Moto
r
i
z
e
d
P
r
o
b
e
H
e
a
d
s
(
1
e
a
c
h
)
Cont
r
o
l
(
e
n
d
l
i
m
i
t
s
,
e
n
c
o
d
e
r
signa
l
s
,
L
E
D
s
)
Con
t
r
o
l
B
o
x
i
n
t
e
r
f
a
c
e
Res
e
r
v
e
s
o
c
k
e
t
s
f
o
r
m
o
t
o
r
i
z
e
d
t
u
r
r
e
t
/
optio
n
s
i
.
e
.
:
A
u
t
o
m
a
t
i
c
p
r
o
b
e
r
i
n
p
u
t
s
Pow
e
r
s
u
p
p
l
y
s
o
c
k
e
t
s
(
x
3
)
IEEE
Prob
e
r
c
o
n
n
e
c
t
i
o
n
s
Add
r
e
s
s
S
w
i
t
c
h
Extra
c
t
o
r
f
a
n
Please also refer to section 2.10 for further information.