4OM-1054-002.pdf - 第220页

Error ID ltem Description 430a03 Oil Cooler Oil cooler operation fails. See if pressure sensor works, or breaker works, or power source incapable. (Cause 1) Self-Diagnostics Error Message (Remedy 1) Zero all axes and re-…

100%1 / 337
Error ID Item Description
430701 Linear Measure Linear measure alarm signal was detected.
430702 Linear Measure Communication error in linear measure system.
430703 Linear Measure Upper limit of linear measure data was out of range.
430704 Linear Measure Lower limit of linear measure data was out of range.
430705 Linear Measure Linear measure dirty signal was detected.
430706 Linear Measure Linear measure SYNC signal has been lost.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
430801 Cam-Positioner Cam-positioner alarm signal was detected.
(Cause 1) The cam positioner is abnormal.
(Remedy 1) Press the [RETURN] button to cancel the error display and contact our service
personnel for the remedy.
430901 Auto Recovery Cannot recover sequence.
430a01 Oil Cooler Oil cooler alarm signal was detected.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
430a02 Oil Cooler Oil cooler flow SW alarm signal was detected.
(Cause 1) The cooling oil filter in the driving section of the main machine may be defective.
(Remedy 1) Replace the oil filter with a new one.
Refer to "Cooling Oil Filter" in "1.3 Maintenance Spots" for the replacement
procedure.
3.3 Error IDs and Remedial Procedures
0307-005 2-102 AGS01ETRP
Error ID ltem Description
430a03 Oil Cooler Oil cooler operation fails. See if pressure sensor works,
or breaker works, or power source incapable.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our ser-
vice personnel for the remedy.
430b01 Cooling FAN Cooling FAN alarm signal was detected.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
430c01 Pickup Position Feedback Feedback value out of range. Please check feeder.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our ser-
vice personnel for the remedy.
430d01 Missing Large Comp. Fdr. Crg. is paused to avoid clash with missing component.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Before activating the feeder axis, shut off the load power and remove the
mispicked component.
Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our ser-
vice personnel for the remedy.
430e01 Air Cylinder Low pressure.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Check the air pressure and zero all axes. After that, re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
3.3 Error IDs and Remedial Procedures
0307-004 2-103 AGS01ETRP
Error ID ltem Description
440101 Cam Phase Gap of cam phase has been detected.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
440201 The Comp. Placement Lever The structure of comp. placement lever was not activated.
;BPH28 E/NR
440202 The Comp. Placement Lever The comp. placement lever moves despite being held by stop-
per.
440203 The Comp. Placement Lever The comp. placement lever does not move even though stop-
per was open.
(Cause 1) The sensor is defective or is not adjusted to the correct position.
The sensor does not turn ON or OFF due to adhered dirt.
(Remedy 1) Wipe off dirt on the sensor and zero all axes again.
3.3 Error IDs and Remedial Procedures
0307-004 2-104 AGS01ETRP