3.3 Error IDs and Remedial Procedures Error ID ltem Description 470801 Comp. Thickness(Sensor) (Cause 1) The machine stopped running because the linear measure detection sensor de- tected the "Component Thickness Er…

100%1 / 337
Error ID ltem Description
470501 Shortage Of Comp. Attach the new comp. And press [READY]. Then, press
[START] button to re-start.
(Cause 1) The tape feeder is empty of components.
(Remedy 1) Re-load the tape feeder with components and press the [READY] button. Then,
re-start the operation.
470601 Group Chip Remove this component. Then, press [START] button to re-
start.
470602 Group Chip Detect the next lot mark in the reset chip.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy
470701 Alternate Feeder Disable Enable alt. And press [READY] button. Then, press [START]
to re-start.
(Cause 1) A component shortage error has occurred on all tape feeders in the group being used
as an objective one for the feeder alternate mode.
(Remedy 1) Press the [RETURN] button to cancel the error display. After that, set "Enable
Exist" for the feeders in the "Alternate Fdr. Mode" group box of the "Alternate" tab
sheet. (Operation Sequence: "OPN. MODE" Window (Submenu) Æ "Alternate"
Tab Sheet)
3.3 Error IDs and Remedial Procedures
0307-006 2-112 AGS01ETRP
3.3 Error IDs and Remedial Procedures
Error ID ltem Description
470801 Comp. Thickness(Sensor)
(Cause 1) The machine stopped running because the linear measure detection sensor de-
tected the "Component Thickness Error (Sensor)" error continuously.
Ref.: When "9" is set in the "2" text box of "Error process" in the component library
data, it means that a pick-up error occurred continuously 9 times on the same
feeder No.
(Remedy 1) Follow the steps below to reset the machine to the normal condition.
(1) Check "Step" and "Feeder No." where an error has occurred.
(2) Press the [RETURN] and [ALL] button (entitled "ZERO"). After that, check
the following items related to the pertinent feeder No.
Check if the tape feeder is loaded with correct components.
Check the selected components and the component library data.
If wrong parameters are set in the component library data, correct them.
Note: Check the parameter set as component thickness check data in
the "CMPNT CARRIAGE DATA EDIT" window.
(3) After taking the required countermeasures, re-start the production.
470901 Cancel Recovery On
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
0307-006 2-113 AGS01ETRP
Error ID ltem Description
470a01 Auto Recovery Pause Attach the new comp. And press [READY]. Then, press
[START] button to re-start.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Follow the described instructions and reset the machine to its normal condition.
480101 DEVICE INSPECT Failed in Issuing the Lighting Selection Command.
480102 DEVICE INSPECT Error Response of Lighting Selection Command!
480103 DEVICE INSPECT Delayed Response of Lighting Selection Command!
480104 DEVICE INSPECT Failed in Issuing the Image Capture Command.
480105 DEVICE INSPECT Error Response of Image Capture Command!
480106 DEVICE INSPECT Failed in Issuing the Recognition Command.
480107 DEVICE INSPECT Delayed Response of Image Capture Command!
480108 DEVICE INSPECT Error Response of Recognition Command!
480109 DEVICE INSPECT Error Response of Recognition Command (Delayed Recogni
tion)!
48010a DEVICE INSPECT Error in Recognition-Related Data Transfer!
48010b DEVICE INSPECT Failed in Issuing the Recognition Interrupt Command.
48010c DEVICE INSPECT Error Response of Recognition Interrupt Command!
48010d DEVICE INSPECT Time-Out of Recognition Interrupt Processing
48010e DEVICE INSPECT Time-Out of Lighting Selection Processing
48010f DEVICE INSPECT Time-Out of Recognition ON Response
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
3.3 Error IDs and Remedial Procedures
0307-006 2-114 AGS01ETRP