4OM-1054-002.pdf - 第284页

3.3 Error IDs and Remedial Procedures Error ID ltem Description 801c03 Information Data was changed during machine worked. The changed data is not reflected in operation until it stops or interrupts opera- tion. (Cause 1…

100%1 / 337
Error ID ltem Description
801a01 Warning Operation Product started by RUN MODE "PASS"Operation.
801a02 Warning Operation The P.C.B. before component placing was conveyed from X/Y
table.
801a03 Warning Operation The P.C.B. in the middle of component placing was conveyed
from X/Y table.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
801b01 Lightning Surge Warning Lightning Surge Protector works; Q204.
801b02 Lightning Surge Warning Lightning Surge Protector works; Q204. Running continue.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
801c01 Information This placement step was detected outside of the possible
range. This step is auto skip running.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
801c02 Information Feeder carriage has been paused to avoid clash with missing
component. Please collect component before operating the
feeder carriage.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Before activating the feeder axis, shut off the power and remove the mispicked
component.
Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
3.3 Error IDs and Remedial Procedures
0307-005 2-166 AGS01ETRP
3.3 Error IDs and Remedial Procedures
Error ID ltem Description
801c03 Information Data was changed during machine worked. The changed data
is not reflected in operation until it stops or interrupts opera-
tion.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
801d01 Semi-auto(continue) start mode Production operation was interrupted for the state where PCB
before component are placed exists on XY table.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
801e01 Placement Level Data Calculated data out of range. Please check library data and
pattern program data.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
801f01 Warm start mode auto change Operation was cancelled for the state where the P.C.B. in the
middle of component placing is on X/Y table.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
809001 Internal Exception Notice CPU2 Vector 0 exception has been disregarded.
809002 Internal Exception Notice CPU2 spurious exception has been disregarded.
809003 Internal Exception Notice CPU2 undefined exception has been disregarded.
809004 Internal Exception Notice CPU3 undefined exception has been disregarded.
809005 Internal Exception Notice EB005 SYSFAIL exception has been disregarded.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
0307-005 2-167 AGS01ETRP
4. Troubleshooting on Recognition System (Error ID)
4.1 Typical Description
Table 4B7
Recognition Error ID Item Description
02**1111** Component Missing Component was not found.
(Cause 1) The feeder carriage is loaded with a feeder that contains components dif-
ferent from the specified ones.
(Cause 2) The vacuum suction force is too weak.
(Cause 3) An improper nozzle is selected for the components or vice versa.
Mismatching parameters are set in the nozzle type data and the compo-
nent library data.
(Remedy 1) Check if proper components are used.
(Remedy 2) Check the vacuum pressure.
(Remedy 3) Check the parameters in the nozzle type data and the component library
data.
02 ******** Error in Outward Length Inspection Component Outward Length X is incorrect.
(Cause 1)
(Remedy 1)
(Continue to next page. )
*1 The recognition error IDs (IDs displayed in the "ERROR" window)
are described in the numerical order.
"*" will be filled with a numeric character.
*2 Described are the error name (item) and the description in the "ER-
ROR" window.
*3 Described are the causes and remedial procedures of the errors in
"*2 (Item and Description)"
The causes and remedies are correlated as follows.
(Cause 1) Æ (Remedy 1)
(Cause 2) Æ (Remedy 2)
(Cause 3) Æ (Remedy 3)
*4 This indicates that the related contents are described subsequently
on the next page.
*1
*2 *3
*2
*4
4. Troubleshooting on Recognition System
0307-005 2-168 AGS01ETRP