4OM-1054-002.pdf - 第280页
3.3 Error IDs and Remedial Procedures Error ID ltem Description 801201 Start Auto Head Recovery Cpu Communication error occurred.(CPU2-CPU3) 801202 Start Auto Head Recovery Head cam origin return action not complete. (No…

3.3 Error IDs and Remedial Procedures
Error ID ltem Description
801001 Auto Offset Teach Information Auto offset teach mode start.(this prcs. Completed)
801002 Auto Offset Teach Information Nozzle not found.
801003 Auto Offset Teach Information Nozzle Dirt Detection. If dirt has adhered, there is a possibil-
ity that it may become impossible to recognize. Please re-
move the dirt adhering to the ring lighting glass upper surface,
a diffusion board, and the nozzle.
801004 Auto Offset Teach Information Gain Level Teach Error.
801005 Auto Offset Teach Information Camera Dirt Detection. If dirt has adhered, there is a possibil-
ity that it may become impossible to recognize. Please re-
move the dirt adhering to the ring lighting glass upper surface,
a diffusion board, and the nozzle.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
801101 Feeder Carriage Priority Mode Return to order of priority carriage.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
0307-004 2-162 AGS01ETRP

3.3 Error IDs and Remedial Procedures
Error ID ltem Description
801201 Start Auto Head Recovery Cpu Communication error occurred.(CPU2-CPU3)
801202 Start Auto Head Recovery Head cam origin return action not complete.
(Not CAM ORIGIN position)
801203 Start Auto Head Recovery Head Driver communication is time out.(from CPU3 job)
801204 Start Auto Head Recovery Nozzle change action not complete.(cam lock action NG)
801205 Start Auto Head Recovery Head cam position return action not complete.
801206 Start Auto Head Recovery Nozzle change action not complete.(cam free action NG)
801207 Start Auto Head Recovery Nozzle change action not complete.
(Not CAM ORIGIN position)
801208 Start Auto Head Recovery Unselected Nozzle Drop.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
801301 Pickup Position Feedback Feedback value out of range. Please check feeder.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
801401 Pickup Level Data Calculated data out of range. Please check library data and
offset data.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
801402 Placement Level Data Calculated data out of range. Please check library data and
offset data.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
0307-005 2-163 AGS01ETRP

3.3 Error IDs and Remedial Procedures
Error ID ltem Description
801501 Feeder Index Position Production operation was interrupted in the middle of feeder
index operation. Please check a position.
801502 Feeder Index Position The feeder carriage was returned to the home position in the
middle of feeder index operation. Please check a feeder index
position.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
801601 Product Restart Restart production with semi-auto(after specified step) mode.
801602 Product Restart Restart production with warm start mode.
801603 Product Restart Restart production with warm start mode after EMER stop.
Machine will stop after placement complete. Please confirm
PCB afterward.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
801701 Teach Nozzle Bypass Nozzle Down Error.(L)
801702 Teach Nozzle Bypass Nozzle Down Error.(H)
801703 Teach Nozzle Bypass Recognition Teach Error.
801704 Teach Nozzle Bypass Teach Error Data.
801705 Teach Nozzle Bypass Lighting Check.
801706 Teach Nozzle Bypass Nozzle Level.
801707 Teach Nozzle Bypass Nozzle Drop
801708 Teach Nozzle Bypass Dummy Nozzle.
801709 Teach Nozzle Bypass Manual Bypass.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
0307-006 2-164 AGS01ETRP