4OM-1054-002.pdf - 第288页
Recognition Error ID Item Description 0131300001 Error in "Camera POSITION X or POSITION Y" ---- Data. 0131300003 Error in "Camera ANGLE" Data. ---- 0131300007 Error in "Camera 1 – 2 X or Y"…

4.3 Recognition Error IDs and Remedial Procedures
4.3.1 Recognition Communication and Data Errors
AA BB C DDDDD
Detail Code
Secondary Error Classification
1: Recognition Communication
Data Range Error
2: Input Data Assembly Error
3: Input Data Error
Primary Error Classification
10 to 70: Communication Commands
90: Communication Procedure
91: Command Error
92: Response Error
Classification (01) of Recognition Functions
When an error ID other than the described ones is issued, con-
tact our service personnel for some advice.
Table 4B9
Recognition Error ID Item Description
01**1***** Error in Recognition Communication Data -----
(Cause) An error was found in the recognition communication data.
(Remedy 1) Contact our service personnel for details.
0121300000 "P.E.C. Lighting #2" is not Connected! -----
(Cause) Failed in confirmation to the connection of the lighting unit for ceramic boards.
(Remedy 1) Contact our service personnel for some advice.
0130300001 Error in "Camera MAGNIFICATION X or -----
MAGNIFICATION Y" Data.
(Cause) Wrong parameters are set.
(Remedy 1) Set the correct data.
4.3 Recognition Error IDs and Remedial Procedures
0307-005 2-170 AGS01ETRP

Recognition Error ID Item Description
0131300001 Error in "Camera POSITION X or POSITION Y" ----
Data.
0131300003 Error in "Camera ANGLE" Data. ----
0131300007 Error in "Camera 1 – 2 X or Y" Data. ----
0132300002 Error in "Camera GAIN or LEVEL" Data. ----
0133300001 Error in "Nozzle Offset High Mag. X or Y" Data. ----
0133300002 Error in "Nozzle Offset Low Mag. X or Y" Data. ----
0133300004 Error in "Nozzle O.D.Size" Data. ----
0133300005 Error in "Nozzle I.D.Size" Data. ----
0133300008 Error in "Nozzle V-Groove Size" Data. ----
0134300001 Error in "Individual Nozzle Gain or Level" Data. ----
0135300001 Error in "Nozzle High or Low level offset" Data. ----
0136300001 Error in "Nozzle Position Offset" Data. ----
0137300001 Error in "Head Center X or Y Offset" Data. ----
(Cause) Wrong parameters are set.
(Remedy) Set correct parameters.
4.3 Recognition Error IDs and Remedial Procedures
0307-005 2-171 AGS01ETRP

Recognition Error ID Item Description
0138200000 Unavailable fiducial mark code was set. ----
0138200001 "Mark Size D2" is too big, compared with "D1". ----
0138200002 "Mark Size D3" is too big, compared with "D1". ----
0138200003 "Mark Size D2" is too big, comapred with"D3". ----
0138200004 "Window Size" is smaller than "Mark Size". ----
0138200005 "Mark Size D2" is not set. ----
0138200006 "Mark Size D3" is not set. ----
0138300001 Error in "P.C.B Recognition Mark Data Mark Size ----
D1 or D2 or D3" Data.
0138300003 Error in "P.C.B Recognition Mark Data Window ----
Size" Data.
(Cause) Wrong parameters are set for the P.E.C. recognition function.
(Remedy) Refer to "Section 2 Pattern Program" in "Vol. 3" for details and set correct
parameters.
4.3 Recognition Error IDs and Remedial Procedures
0307-005 2-172 AGS01ETRP