Fitting the Vacuum Pump Preparatory Steps 3.3.3 Fitting the Vacuum Pump Connection Unit SX1/2 [03079949- xx] on Ma - 100 Vacuum Pump Vakuumpumpe 3.3.3 3 . 3 . 3 F it t in g t h e V a c u u m P u m p C o n n e c t io n U …

Fitting the Vacuum Pump
3.3.2 Prefitting the Vacuum Pump Preparatory Steps
Vacuum Pump Vakuumpumpe 99
1,2 fixture points for vacuum pump
► Connect the vacuum pump [03069679-xx] to the car-
riage [03077380-xx] as shown in the photo.
► Fix the vacuum pump to the carriage (at positions (1)
and (2) and on the opposite side). Use the type
ISO4762-M5x30-A2-70 screws [03042565-xx] for
this.
1 Fixture point for cable clamps
2, 3 Guiding the power cable upwards
► Fit the two cable clamps onto the power cable.
► Fix the two cable clamps to position 1. In each case,
place a washer between the cable clamp
[00386753-xx] and the screw (ISO4762-M4x8-A2-70)
[03042551-xx].
► Run the power cable upwards (2) and over the
pump (3).

Fitting the Vacuum Pump
Preparatory Steps 3.3.3 Fitting the Vacuum Pump Connection Unit SX1/2 [03079949-xx] on Ma-
100 Vacuum Pump Vakuumpumpe
3.3.3
3.3.3 Fitting the Vacuum Pump Connection Unit SX1/2 [03079949-xx] on Machines Kxxx / Lxxx / Mxxx
Fitting the Vacuum Pump Connection Unit SX1/2 [03079949-xx] on Machines Kxxx /
Lxxx / Mxxx
Variant 1
► Remove the two screws (1).
► Remove the plate (2).
The electrical connection unit is installed in the location 2
area.
► Remove the cover from the power supply.
The plate is clipped into the machine frame. Take
hold of the loop (1) and pull it out.
► On machines from N001, remove the cover (2) from
the machine base.

Fitting the Vacuum Pump
3.3.3 Fitting the Vacuum Pump Connection Unit SX1/2 [03079949-xx] on Machines Kxxx / Lxxx / Mxxx Preparatory Steps
Vacuum Pump Vakuumpumpe 101
Variant 2
1. Fixture points for connection unit
2. Connector X102
3. Cable X103
► The vacuum pump connection unit [03079949-xx] is
fitted to a mounting rail. Use the screws provided to
fix the vacuum pump connection unit to the two posi-
tions shown here (1).
► After installing the pump, connect the cable
[03079997-xx] for the vacuum pump power supply to
terminal X106 of the connection unit (1).
► Connect the cable [03087337-xx] upgrade kit (cable:
vacuum pump connection unit) between X102 for the
transformer unit and X105 for the vacuum pump con-
nection unit (2).
► Connect the cable [03072544-xx] (cable: vacuum
pump control), which is already in the machine, to
X103 for the connection unit (3).
Transformer unit (without terminals) (1)