00196614-03_AI_Vakuumpumpe_SXDX12_de_en.pdf - 第99页
Fitting the Vacuum Pump 3.3.2 Prefitting the Vacuum Pump Preparatory Steps Vacuum Pump Vakuumpumpe 99 1,2 fixture points for vacuum pu mp ► Connect the vacuum pump [03069679 - xx] to the car - riage [03077380 - xx] a s s…

Fitting the Vacuum Pump
Preparatory Steps 3.3.2 Prefitting the Vacuum Pump
98 Vacuum Pump Vakuumpumpe
3.3.2.6
3.3.2.6 Installing and Adjusting the Leakage Valve
Installing and Adjusting the Leakage Valve
The leakage valve is closed completely with two placement heads in vacuum mode.
If only one placement head is to be operated with the vacuum pump, the valve must be opened by a ½
rotation.
3.3.2.7
3.3.2.7 Placing the Vacuum Pump onto the Slide
Placing the Vacuum Pump onto the Slide
► Dismantle the distribution block from the vacuum
pump.
► Unscrew a Festo screw joint (1).
► Mount the ½ inch (1) to 1 inch (2) adapter and the
Becker vacuum valve (3).
Vacuum pump slide
1. Fixture points for cable clamps
2. Nibs for subsequent fixture of slide to exhaust air duct
3. 4 fixture points for vacuum pump

Fitting the Vacuum Pump
3.3.2 Prefitting the Vacuum Pump Preparatory Steps
Vacuum Pump Vakuumpumpe 99
1,2 fixture points for vacuum pump
► Connect the vacuum pump [03069679-xx] to the car-
riage [03077380-xx] as shown in the photo.
► Fix the vacuum pump to the carriage (at positions (1)
and (2) and on the opposite side). Use the type
ISO4762-M5x30-A2-70 screws [03042565-xx] for
this.
1 Fixture point for cable clamps
2, 3 Guiding the power cable upwards
► Fit the two cable clamps onto the power cable.
► Fix the two cable clamps to position 1. In each case,
place a washer between the cable clamp
[00386753-xx] and the screw (ISO4762-M4x8-A2-70)
[03042551-xx].
► Run the power cable upwards (2) and over the
pump (3).

Fitting the Vacuum Pump
Preparatory Steps 3.3.3 Fitting the Vacuum Pump Connection Unit SX1/2 [03079949-xx] on Ma-
100 Vacuum Pump Vakuumpumpe
3.3.3
3.3.3 Fitting the Vacuum Pump Connection Unit SX1/2 [03079949-xx] on Machines Kxxx / Lxxx / Mxxx
Fitting the Vacuum Pump Connection Unit SX1/2 [03079949-xx] on Machines Kxxx /
Lxxx / Mxxx
Variant 1
► Remove the two screws (1).
► Remove the plate (2).
The electrical connection unit is installed in the location 2
area.
► Remove the cover from the power supply.
The plate is clipped into the machine frame. Take
hold of the loop (1) and pull it out.
► On machines from N001, remove the cover (2) from
the machine base.