00196614-03_AI_Vakuumpumpe_SXDX12_de_en.pdf - 第120页

Fitting the Vacuum Pump Final Wo rk 3.5.2 Conversion for C&P12 120 Vacuum Pump Vakuumpumpe

100%1 / 134
Fitting the Vacuum Pump
3.5.2 Conversion for C&P12 Final Work
Vacuum Pump Vakuumpumpe 119
3.6
3.6 Final Work
Final Work
Fit the cover over the vacuum pump.
Install the used tape chute.
Compone nt Supply - Manual Tables - Fitting Pr otections - Color Version
If you have removed the table height adjustment and the calibration tool holder, refit these.
If you have opened the cover on the cable duct and left it up during the conversion work, close it
again now.
Refit the center cover on the distributor and fix into place.
Dock the component trolleys onto the SX machines.
Re-insert the manual table into DX machines.
Switch the machine on.
Open the compressed air shut-off valve.
Push the pneumatic unit into the machine.
Close all doors.
Switch the machine on at the main switch.
Manual tables only:
WARNING!
There is a risk of injury on manual tables without the two
protections.
Fit the two protections:
Protection waste chute DX1/2 left [03094519-xx]
Protection waste chute DX1/2 right [03094522-
xx]
CAUTION
Switch-on preconditions
Before switching on, perform the following checks to prevent injuries or serious damage to
property:
Make sure of the following before you switch the compressed air supply back on:
Check that all hose connections are correctly assigned. Make sure that no compressed air
can get into a vacuum hose.
Check that all conditions for switch-on of the vacuum pump and connected placement ma-
chine have been fulfilled. Read the corresponding operation manuals for more information.
Make sure that the vacuum pump is always switched on before the machine.
Fitting the Vacuum Pump
Final Work 3.5.2 Conversion for C&P12
120 Vacuum Pump Vakuumpumpe
Maintenance
4.1.1 Tools, Consumables, Spare and Wear Parts Maintenance Tasks for Vacuum Pump
Vacuum Pump Vakuumpumpe 121
4
4 Maintenance
Maintenance
See also
3.3.2 Prefitting the Vacuum Pump [ ➙ 92]
4.1
4.1 Maintenance Tasks for Vacuum Pump
Maintenance Tasks for Vacuum Pump
SXDX12V2 The vacuum pum p is an opti on
4.1.1
4.1.1 Tools, Consumables, Spare and Wear Parts
Tools, Consumables, Spare and Wear Parts
If needed, filter insert [03077677-xx]
SXDX12V2
Assembly instructions for vacuum pump SX1/SX2 [00196614-xx]
Service manual for your machine
4.1.2
4.1.2 Preparatory Steps
Preparatory Steps
Risk of injury when working near the tap e cutter
Switch off the machine and secure it to prevent unauthorized reactivation. Observe the instructions
in section "1.2 Preparatory Work..." [ 73].
Interrupt the compressed air supply to the machine.
SXDX12V2
Dismantle the waste slide. Read the service manual for your machine first.
Dismantle the cover plate over the vacuum pump.
NOTICE
Observe the maintenance instructions!
The following chapters are only excerpts from the maintenance manual.
Refer to the maintenance manual for your machine if you need complete information about
maintenance for the vacuum pump.
NOTICE
The vacuum pump is an option.
The vacuum pump is located at location 2 behind the COT-insert.
WARNING
Risk of injury when working near the cutter.
When working in the area of the tape cutter, move the component trolley out of the machine
and disconnect the machine from the mains supply and the compressed air supply.
Wait until the operating pressure has dropped to 0 MPa.
Always secure the machine against unauthorized reactivation.
Do not reach into the tape cutter.
CAUTION
Make sure you do not damage any cables and hoses.
CAUTION
Loosened vacuum pump
It is possible to remove the vacuum pump from the machine but it is not necessary.
For a better access, however, it may be useful to loosen the vacuum pump and pull it a bit to
the front within the machine. Also read the Assembly Instructions for the vacuum pump.
Make sure that the vacuum pump cannot fall out of the machine.