DFD6361-Maintenance.pdf - 第395页

D-110 A0535 : Index check Y position error . (Y) Error c ode A0535 Message Index check Y posit ion error . (Y) W hat wa s detected In searching a patt ern durin g Y -direction movem ent in index che ckout, the Y -coordin…

100%1 / 720
D-109
A0534 : Not found index check target.
Error code
A0534
Message
Not found index check target.
What was
detected
Error display is done if the pattern is not found during index checkout after
alignment.
During what
operation it
occurred
During auto alignment operation.
State after
detection
Auto alignment operation is temporarily halted.
Phenomenon Probable causes Remedy Reference
What to do
The error occurs
frequently.
The workpiece is
partially soiled.
Perform the manual
alignment and then
continue machining
the workpiece.
Recovery
(1) Cancel the alarm, then the ERROR RECOVERY (ALIGNMENT)
screen is displayed.
(2) Perform the error recovery steps indicated on the screen.
Maintenance level Maintenance personnel level Hazard level
Measuring equipment used Tools Replacement parts Protective gear
D-110
A0535 : Index check Y position error. (Y)
Error code
A0535
Message
Index check Y position error. (Y)
What was
detected
In searching a pattern during Y-direction movement in index checkout, the
Y-coordinate exceeded the preset value in the column <INDEX CHECK:
PERMISSION> on the ALIGNMENT DATA screen [screen 3.1.3]
During what
operation it
occurred
During Y-direction movement in index checkout of auto alignment
operation.
State after
detection
Auto alignment operation is temporarily halted.
Phenomenon Probable causes Remedy Reference
What to do
The error occurs
frequently.
The value specified
in the column
<INDEX CHECK:
PERMISSION> on
the ALIGNMENT
DATA screen [screen
3.1.3] is too small.
Correct the value
specified in the
column <INDEX
CHECK:
PERMISSION> on
the ALIGNMENT
DATA screen
[screen 3.1.3].
Recovery
(1) Cancel the alarm, then the ERROR RECOVERY (ALIGNMENT)
screen is displayed.
(2) Perform the error recovery steps indicated on the screen.
Maintenance level Maintenance personnel level Hazard level
Measuring equipment used Tools Replacement parts Protective gear
D-111
A0536 : Index check X position error. (X)
Error code
A0536
Message
Index check X position error. (X)
What was
detected
In searching a pattern during X-direction movement in index checkout, the
Y-coordinate exceeded the preset value in the column <INDEX CHECK:
PERMISSION> on the ALIGNMENT DATA screen [screen 3.1.3].
During what
operation it
occurred
During X-direction movement in index checkout of auto alignment
operation.
State after
detection
Auto alignment operation is temporarily halted.
Phenomenon Probable causes Remedy Reference
What to do
The error occurs
frequently.
The value specified
in the column
<INDEX CHECK:
PERMISSION> on
the ALIGNMENT
DATA screen [screen
3.1.3] is too small.
Correct the value
specified in the
column <INDEX
CHECK:
PERMISSION> on
the ALIGNMENT
DATA screen
[screen 3.1.3].
Recovery
(1) Cancel the alarm, then the ERROR RECOVERY (ALIGNMENT)
screen is displayed.
(2) Perform the error recovery steps indicated on the screen.
Maintenance level Maintenance personnel level Hazard level
Measuring equipment used Tools Replacement parts Protective gear